U464 Setting The Id Correction Operation - Kyocera TASKalfa 250ci Service Manual

Hide thumbs Also See for TASKalfa 250ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-1
Maintenance
item No.
Setting the ID correction operation
U464
Description
Turns ID correction (calibration) on or off. Also, this determines the duration of calibration and the timing of
calibration during printing. Also, this allows individual settings for calibration operation by enabling custom set-
tings.
Purpose
To restrict calibration when poor image quality is generated. Also, this allows individual settings for calibration
by enabling custom settings in setting the calibration cycle under the machine defaults depending on the user
preferences.
Performs AC calibration when replacing the developing or drum unit.
Method
1. Press the start key.
2. Select the item to be set. The setting screen for the selected item is displayed.
Display
Permission
Set Time Interval
Set Sleep Period for
Calib
Permission
Act.(50sheets)
Permission
(ON/Sleep out)
Permission (AP/NE)
SetCalib Timing
duringPrint
Set Interval
CalibDriveTime
Set Interval
CalibPrint Rate
Set Custom
AC Calibration
Setting: [Permission]
1. Select ON or OFF.
Display
ON
OFF
Initial setting: ON
2. Press the start key. The setting is set.
Setting: [Set Time Interval]
1. Change the setting value using the +/- or numeric keys.
Display
COUNT
2. Press the start key. The setting is set.
1-3-120
Description
Description
Setting to turn calibration on/off
Setting the interval time of calibration after printing
Setting the standard time for judging whether or not to carry out calibration
based on the sleep time when the machine recovers from the sleep mode.
Turning paper interval calibration on/off after continuously printing 50 pages
Setting execution parameters for calibration when powered up or reverted
from auto-sleep
Paper interval calibration ON/OFF setting at the time of calibration/near end
after toner feed
Setting the standard time for judging whether or not to carry out calibration
based on the continuous print driving time during printing.
Setting the standard time for judging whether or not to carry out paper inter-
val calibration based on the driving time during printing.
Setting the standard printing ratio for judging whether or not to carry out cal-
ibration based on the printing ratio when printing the tenth sheet.
Turning custom settings on/off in setting the calibration cycle under the
machine defaults
Executing the AC calibration
Description
Turns calibration ON
Turns calibration OFF
Description
Setting the interval time of calibration
Setting range
Initial setting
0 to 9999 (s)
480