U021 Memory Initializing; U024 Hdd Formatting - Kyocera TASKalfa 250ci Service Manual

Hide thumbs Also See for TASKalfa 250ci:
Table of Contents

Advertisement

Maintenance
item No.
Memory initializing
U021
Description
Initializes all settings, except those pertinent to the type of machine, namely each counter, service call history
and mode setting. Also initializes backup RAM according to region specification selected in maintenance item
U252 Setting the destination.
Refer to *1 of the maintenance mode item list about the item initialized.
Purpose
To return the machine settings to their factory default.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key. All data other than that for adjustments due to variations between machines is initial-
ized based on the destination setting.
4. Turn the main power switch off and on.
An error code is displayed in case of an intialization error.
When ERROR 09 occurred, turn main power switch off then on, format the hard disk using maintenance
item U024, and execute initialization using maintenance item U021. For other errors occurred, turn main
power switch off then on, and execute initialization using maintenance item U021.
Error codes
HDD formatting
U024
Description
Initializes the HDD.
In addition, the following settings are also initialized by initializing the HDD.
System menu (user login administration, job accounting, address book, one-touch keys and document box
etc.), shortcuts and panel programs
Purpose
To initialize the HDD when replacing the HDD after shipping.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key to initialize the hard disk.
4. Turn the main power switch off and on.
Codes
Description
ERROR 01
Configuration initialization error
ERROR 02
Counter initialization error
ERROR 03
One-touch initialization error
ERROR 04
Panel program initialization error
ERROR 05
Event log initialization error
ERROR 06
Account initialization error
ERROR 07
Address book initialization error
ERROR 08
Department initialization error
ERROR 09
Document box initialization error
ERROR 0a
Permissibility initialization error
ERROR 0b
Job log initialization error
ERROR 20
Engine initialization error
ERROR 40
Scanner initialization error
Description