Connector
Pin No.
1
TB
Connected
2
to the inlet
and main
3
power
switch
1
YC1
Connected
2
to the main
power
switch
1
YC2
Connected
2
to the
3
optional
paper feeder
1
YC3
Connected
2
to the cas-
sette heater
3
1/2
4
5
6
1
YC4
Connected
2
to the fuser
heater 1/2/3
3
4
YC5
1
Connected
2
to the ISM
3
PWB and
4
optional DP
5
6
7
8
9
10
Signal
I/O
AC_LIVE
I
AC_NEUTRAL
I
HEATER LIVE
-
MSW_IN
I
MSW_OUT
O
DH2_LIVE
O
NC
-
DH2_NEUTRAL
O
DH3_LIVE
O
DH3_LIVE
O
NC
-
NC
-
DH3_NEUTRAL
O
DH3_NEUTRAL
O
H_LIVE
O
SH_OUT
O
PR_OUT
O
MH_OUT
O
24V1
O
24V1
O
12V1
O
5V1
-
5V1
O
GND
-
GND
-
GND
-
GND
-
GND
-
Voltage
120 V AC
AC power input
220-240 V AC
120 V AC
AC power input
220-240 V AC
-
Not used
120 V AC
AC power input from MSW
220-240 V AC
120 V AC
AC power input from MSW
220-240 V AC
120 V AC
AC power output to CH (option)
220-240 V AC
-
Not used
120 V AC
AC power output to CH (option)
220-240 V AC
120 V AC
AC power output to CH1
220-240 V AC
120 V AC
AC power output to CH2
220-240 V AC
-
Not used
-
Not used
120 V AC
AC power output to CH1
220-240 V AC
120 V AC
AC power output to CH2
220-240 V AC
120 V AC
AC power to FH1/2/3
220-240 V AC
120 V AC
FH2: On/Off
220-240 V AC
120 V AC
FH3: On/Off
220-240 V AC
120 V AC
FH1: On/Off
220-240 V AC
24 V DC
24 V DC power to ISMPWB
24 V DC
24 V DC power to DPDPWB
12 V DC
12 V DC power to ISMPWB
-
Not used
5 V DC
5 V DC power to DPDPWB
-
Ground
-
Ground
-
Ground
-
Ground
-
Ground
2JZ/2JX/2JV/2H7-1
Description
2-3-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 300ciTaskalfa 500ciTaskalfa 400ci

Table of Contents