2JZ/2JX/2JV/2H7-1
Maintenance
item No.
Resetting partial operation control
U906
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the cassettes or other sections, and the
related parts are serviced.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key to reset partial operation control.
4. Turn the main power switch off and on.
Checking the total counter value
U908
Description
Displays the total counter value.
Purpose
To check the total counter value.
Method
1. Press the start key. The screen for total count value is displayed.
Display
Total Count
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Clearing the coverage data
U910
Description
Clears the accumulated data for the coverage per A4 size paper in all colors.
Purpose
To clear data as required at times such as during maintenance service.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key. The coverage data is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking/clearing copy counts by paper sizes
U911
Description
Displays and clears the paper feed counts by paper sizes.
Purpose
To check or clear the counts after replacing consumable parts.
Method
Press the start key. The screen for the paper feed counts by paper size is displayed.
Clearing
1. Select the paper size to be cleared.
Select the counts for all and press [ALL CLEAR].
2. Press the start key. All counts are cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-134
Description
Description
Total count value