2JZ/2JX/2JV/2H7-1
Maintenance
item No.
Setting for MODE3
U147
1. Select [Set Value].
2. Select the color to be set.
3. Change the setting value using +/- keys.
Display
Black
Cyan
Magenta
Yellow
4. Press the start key. The setting is set.
5. Select [Set MODE].
Setting: [Upper Limit]
1. Change the setting value using the +/- keys.
Display
Upper Limit
2. Press the start key. The value is set.
Setting: [Sleeve Cleaning]
1. Change the setting value using the +/- keys.
Display
Sleeve Clean Int
2. Press the start key. The value is set.
Setting: [Set Drum Cleaning Mode]
Modify settings only if faulty images, such as smear, occurs in a high humid environment.
1. Select the mode to be set.
Display
MODE1
MODE2
Initial setting: MODE1
2. Press the start key. The setting is set.
Setting: [Set Minimum Value]
1. Change the setting value using the +/- keys.
Display
Minimum Value
The initial setting value depends on the setting of [Set Drum Cleaning Mode].
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-74
Description
Description
The magnification ratio which is multiplied
in the toner applying quantity for black
The magnification ratio which is multiplied
in the toner applying quantity for cyan
The magnification ratio which is multiplied
in the toner applying quantity for magenta
The magnification ratio which is multiplied
in the toner applying quantity for yellow
Description
Upper limit printing ratio of toner applying
quantity with each mode
Description
Toner collection operational interval on
developing sleeve after the toner applying
operation (T7 control)
Description
Constitutes a toner layer if the print coverage is less than 2%.
(excludes the maximum paper width A3/A4)
Apply toner regardless of the current print coverage.
Description
Toner layer width (mm)
Setting range
Initial setting
0 to 5.0
1.0
0 to 5.0
1.0
0 to 5.0
1.0
0 to 5.0
1.0
Setting range
Initial setting
0 to 10 (%)
5 (%)
Setting range
Initial setting
10 to 300 (s)
60 (s)
Setting range
Initial setting
0 to 30 (mm)
MODE1: 10
MODE2: 20