(1) Detaching and refitting the exposure lamp
Follow the procedure below to replace the exposure lamp.
Procedure
1. Remove the original platen or DP.
2. Remove the rear upper filter cover.
3. Remove nine screws and remove the rear
upper cover.
4. Open the front cover.
5. Remove the clip support.
6. Remove two screws and remove front left
cover 1.
Rear upper cover
Screws
Screw
Screw
Screw
Screw
Clip support
2JZ/2JX/2JV/2H7-1
Rear upper
filter cover
Screw
Screw
Screw
Figure 1-5-17
Screw
Front left
cover 1
Screw
Figure 1-5-18
1-5-11