(2) Detaching and refitting the scanner wires

Take the following procedure when the scanner wires are broken or to be replaced.
NOTE
When fitting the wires, be sure to use those specified below.
Machine front: (P/N: 302H717380), black
Machine rear: (P/N: 302H717390), gray
Fitting requires the following tools
Two frame securing tools (P/N 302FZ17100)
Two scanner wire stoppers (P/N 3596811)
Procedure
Detaching the scanner wires
1. Remove the exposure lamp (see page 1-5-
11).
2. Remove each screw and then remove front
and rear wire holder plates from mirror 1
frame.
3. Remove the mirror 1 frame.
Mirror 1 frame
Screw
Front wire
holder plate
Mirror 1 frame
Figure 1-5-26
2JZ/2JX/2JV/2H7
Rear wire
holder plate
Screw
Mirror 1 frame
1-5-15