Chap Setting Command; Chap - Huawei OceanStor S2600 Command Reference Manual

Storage system v100r002
Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

OceanStor S2600 Storage System
Command Reference
Example
Change the system time to 2008-12-17/11:05:00.
OceanStor: admin> chgsystime -t 2008-12-17/11:05:00

4.10 CHAP Setting Command

CHAP setting command is used to create, change, delete, and query CHAP user.

4.10.1 chap

4.10.1 chap
Function
The command chap is used to set CHAP-related functions for iSCSI host ports.
Format
chap { -adduser -user username -password password |-adduser -initiator initiator name -
user username |-chgpassword -user username -password password |-showuser [ -initiator
initiator name ] |-deluser [ -initiator initiator name] -user username1...usernameN | -
showinitiator [ -user username | -free ] |-chgchapuser -initiator initiator name1...initiator
nameN -status { START | STOP } |-addinitiator -initiator initiator name1 ...initiator
nameN |-delinitiator -initiator initiator name1 ...initiator nameN }
Parameters
Keyword and Value
-adduser -user username -
password password
Issue 07 (2010-05-20)
Description
The command provides the
functions of adding a CHAP
user and setting the
password.
-user username:
l
CHAP user name. The
name contains 4 to 25
characters, including
numbers, letters,
underscores, and hyphens.
The first character must be
a letter.
-password password:
l
The password. It contains
12 to 16 characters.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 System Management Commands
Default Value
None.
4-33