Disconnecttgt - Huawei OceanStor S2600 Command Reference Manual

Storage system v100r002
Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

OceanStor S2600 Storage System
Command Reference
Usage Guidelines
The chgtgt command requires the compulsory parameters -c and -ti, and at least one optional
parameter.
Example
Change IP address of the target on controller A with the ID of 0.to 128.23.25.26, TCP/IP
port to 1234, and Link recovery policy to Auto.
OceanStor: admin> chgtgt -c a -ti 0 -ip 128.23.25.26 -port 1234 -m 1
System Response
When the command is complete, you can run the showtgt command to view the result.

9.4.5 disconnecttgt

Function
The command disconnecttgt is used to disconnect a target (controller) from the initiator.
Format
disconnecttgt -c controller ID -ti Target ID
Parameters
Keyword and Value Description
-c controller ID
-ti Target ID
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
None.
Example
Disconnect the target with the ID of 1 on controller A.
Issue 07 (2010-05-20)
The ID of the connected controller . The value is A
or B, and it is case insensitive.
The target ID. The value ranges from 0 to 7.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Value-Added Service Management Commands
Default Value
None.
None.