Showlunforhyimg - Huawei OceanStor S2600 Command Reference Manual

Storage system v100r002
Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

9 Value-Added Service Management Commands
Parameters
Keyword and Value Description
-i pool ID
-v alarm value
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
None.
Example
Set the alarm threshold of pool A to 70.
OceanStor: admin> chgpoolalarmvalue -i a -v 70
System Response
When the command is complete, you can run the showpoolinfo command to view the result.

9.1.9 showlunforhyimg

Function
The command showlunforhyimg is used to query information of all qualified LUNs that are to
be used as source LUNs of HyperImages. The information includes the LUN name, LUN ID,
capacity, the raid group that the LUN belongs to, and the level of the RAID group.
Format
showlunforhyimg
Parameters
None.
9-10
The resource pool ID. The value is A or B, and it is
case insensitive.
The alarm threshold. The value ranges from 50 to
100.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OceanStor S2600 Storage System
Command Reference
Default Value
None.
None.
Issue 07 (2010-05-20)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents