5A-96 AUTOMATIC TRANSMISSION
9. Check that the cam collar slides freely on the rod.
10. Insert the cross shaft into the case, from the side opposite
to the inhibitor switch, then install the anti-rattle spring on
the shaft.
11. Position the manual valve detent lever, aligning it with the
cross-shaft bore in the case.
12. Push the shaft through the detent lever until it starts in the
detent lever side of the case.
13. Install the detent lever drive pin in the shaft using tool No.
0555-331897 with the adaptor over the pin.
14. Press the pin into the shaft until the tool bottoms.
15. Remove the tool and fit the spring retaining circlip to the
shaft.
16. Install the new cross shaft seals using tool No. 0555-
331894.
17. Install the inhibitor switch on the case. Torque the screws
as per specifications. Press the pin into the shaft until the
tool bottoms (4WD models) using tool No.0555-332942.
18. Thoroughly check the terminal wiring loom for condition
and continuity.
19. Position the loom and locate the solenoid 7 contact and
terminal in the pump mounting flange at the front of the
case. The solenoid 7 wire is routed under the park rod
and cross shaft in the case.