Crankcase
• Install the dowel pins and O-ring (1).
CAUTION
!
Replace the O-rings with new ones.
1
• Apply bond to the mating surface of the lower
crankcase as follows.
NOTE
• Make surfaces free from moisture, oil, dust
and other foreign materials.
• Spread the sealant on surfaces thinly to
form an even layer, and assemble the
crankcases within a few minutes.
• Take extreme care not to apply sealant to
any oil hole, oil groove and bearing.
• Apply sealant to distorted surfaces as it
forms a comparatively thick film.
: Sealant 99000–31140 (SUZUKI BOND
No.1207B or equivalent)
I838H1140044-01
: Apply bond.
Engine Mechanical:
1D-61