| Security Measures
C
13
HAPTER
IPv4 Source Guard
P
ARAMETERS
These parameters are displayed:
Filter Type – Configures the switch to filter inbound traffic based
◆
source IP address, or source IP address and corresponding MAC
address. (Default: None)
None – Disables IP source guard filtering on the port.
■
SIP – Enables traffic filtering based on IP addresses stored in the
■
binding table.
SIP-MAC – Enables traffic filtering based on IP addresses and
■
corresponding MAC addresses stored in the binding table.
Max Binding Entry – The maximum number of entries that can be
◆
bound to an interface. (Range: 1-5; Default: 5)
This parameter sets the maximum number of address entries that can
be mapped to an interface in the binding table, including both dynamic
entries discovered by DHCP snooping (see
page
404) and static entries set by IP source guard (see
Static Bindings for IP Source Guard" on page
W
I
EB
NTERFACE
To set the IP Source Guard filter for ports:
Click Security, IP Source Guard, Port Configuration.
1.
Set the required filtering type for each port.
2.
Click Apply
3.
Figure 220: Setting the Filter Type for IP Source Guard
– 400 –
"IPv6 Source Guard" on
"Configuring
401).