Edge-Core ES3528MV2 Management Manual page 251

Edge-core 28-port fast ethernet layer 2 switch
Table of Contents

Advertisement

An interface cannot function as an edge port under the following
conditions:
If spanning tree mode is set to STP
cannot automatically transition to operational edge-port state using
the automatic setting.
If loopback detection is enabled
detected, the interface cannot function as an edge port until the
loopback state is released.
If an interface is in forwarding state and its role changes, the
interface cannot continue to function as an edge port even if the
edge delay time has expired.
If the port does not receive any BPDUs after the edge delay timer
expires, its role changes to designated port and it immediately
enters forwarding state (see
on page
252).
BPDU Guard – This feature protects edge ports from receiving BPDUs.
It prevents loops by shutting down an edge port when a BPDU is
received instead of putting it into the spanning tree discarding state. In
a valid configuration, configured edge ports should not receive BPDUs.
If an edge port receives a BPDU an invalid configuration exists, such as
a connection to an unauthorized device. The BPDU guard feature
provides a secure response to invalid configurations because an
administrator must manually enable the port. (Default: Disabled)
BPDU Filter – BPDU filtering allows you to avoid transmitting BPDUs
on configured edge ports that are connected to end nodes. By default,
STA sends BPDUs to all ports regardless of whether administrative edge
is enabled on a port. BDPU filtering is configured on a per-port basis.
(Default: Disabled)
Migration – If at any time the switch detects STP BPDUs, including
Configuration or Topology Change Notification BPDUs, it will
automatically set the selected interface to forced STP-compatible
mode. However, you can also use the Protocol Migration button to
manually re-check the appropriate BPDU format (RSTP or STP-
compatible) to send on the selected interfaces. (Default: Disabled)
W
I
EB
NTERFACE
To configure interface settings for STA:
Click Spanning Tree, STA.
1.
Select Configure Interface from the Step list.
2.
Select Configure from the Action list.
3.
Modify any of the required attributes.
4.
Click Apply.
5.
– 251 –
| Spanning Tree Algorithm
C
8
HAPTER
Configuring Interface Settings for STA
(page
242), edge-port mode
(page
240) and a loopback BPDU is
"Displaying Interface Settings for STA"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es3528mv2-dc

Table of Contents