Edge-Core ES3528MV2 Management Manual page 209

Edge-core 28-port fast ethernet layer 2 switch
Table of Contents

Advertisement

Configuration Limitations for QinQ
The native VLAN of uplink ports should not be used as the SPVLAN. If
the SPVLAN is the uplink port's native VLAN, the uplink port must be an
untagged member of the SPVLAN. Then the outer SPVLAN tag will be
stripped when the packets are sent out. Another reason is that it
causes non-customer packets to be forwarded to the SPVLAN.
Static trunk port groups are compatible with QinQ tunnel ports as long
as the QinQ configuration is consistent within a trunk port group.
The native VLAN (VLAN 1) is not normally added to transmitted frames.
Avoid using VLAN 1 as an SPVLAN tag for customer traffic to reduce the
risk of misconfiguration. Instead, use VLAN 1 as a management VLAN
instead of a data VLAN in the service provider network.
There are some inherent incompatibilities between Layer 2 and Layer 3
switching:
Tunnel ports do not support IP Access Control Lists.
Layer 3 Quality of Service (QoS) and other QoS features containing
Layer 3 information are not supported on tunnel ports.
Spanning tree bridge protocol data unit (BPDU) filtering is
automatically disabled on a tunnel port.
General Configuration Guidelines for QinQ
Enable Tunnel Status, and set the Tag Protocol Identifier (TPID) value of
1.
the tunnel access port (in the Ethernet Type field). This step is required
if the attached client is using a nonstandard 2-byte ethertype to
identify 802.1Q tagged frames. The default ethertype value is 0x8100.
(See
"Enabling QinQ Tunneling on the Switch" on page
Create a Service Provider VLAN, also referred to as an SPVLAN (see
2.
"Configuring VLAN Groups" on page
Configure the QinQ tunnel access port to Access mode (see
3.
Interface to a QinQ Tunnel" on page
Configure the QinQ tunnel access port to join the SPVLAN as an
4.
untagged member (see
page
198).
Configure the SPVLAN ID as the native VID on the QinQ tunnel access
5.
port (see
"Adding Static Members to VLANs" on page
Configure the QinQ tunnel uplink port to Uplink mode (see
6.
Interface to a QinQ Tunnel" on page
Configure the QinQ tunnel uplink port to join the SPVLAN as a tagged
7.
member (see
"Adding Static Members to VLANs" on page
– 209 –
C
HAPTER
196).
213).
"Adding Static Members to VLANs" on
213).
| VLAN Configuration
6
IEEE 802.1Q Tunneling
210.)
"Adding an
198).
"Adding an
198).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es3528mv2-dc

Table of Contents