1.3 MINIMUM SPACE REQUIREMENTS

30 cm (11.8")
1. Front: 70 cm (27.6")
2. Back: 10 cm (3.9")
3. Right: 60 cm (23.6")
4. Left: 30 cm (11.8")
NOTE: A space of at least 10cm (3.9") at the rear of the machine is
necessary for smooth air inlet into the machine.

1.4 POWER REQUIREMENTS

1. Input voltage level:
110 V/60 Hz : More than 15 A
115 V/60 Hz : More than 15 A (U.S. Version)
220–240 V/50 Hz : More than 8 A
220 V/60 Hz : More than 8 A
220 V/50 Hz : More than 8 A
2. Permissible voltage fluctuation:
3. Do not set anything on the power cord.
NOTE: a) Be sure to ground the machine. (Do not connect the
grounding wire to a gas pipe.)
b) Make sure the plug is firmly inserted in the outlet.
c) Avoid multi-wiring.
A151/A152
10 cm (3.9")
70 cm (27.6")
±
10%
3-2
60 cm (23.6")
FSM