6.5 CHARGE CORONA GRID PLATE REPLACEMENT

1. Open the front cover.
2. Remove the charge corona unit together with wire cleaner (1 screw).
3. Unhook the grid plate anchor [A].
4. Remove the grid plate [B] as shown.
NOTE: a) Oils and chemicals from your hands will deteriorate the grid plate.
b) Do not bend the grid plate. This can result in an uneven charge.
c) When installing the charge corona unit, make sure that the corona
wires are positioned between the cleaner pads (See Charge
Corona Wire Replacement).
FSM
[B]
5-47
[A]