15.6 SP MODE 9–OUTPUT CHECK
– How to turn electrical components on/off –
1. Enter SP mode 9 as outlined in the Service Program Mode Access
Procedure on page 8-34, then press the

2. Enter the desired number from the following table.

3. Press the
key to turn on the electrical component.
4. Press the
key to turn off the electrical component.
Number
1
Main Motor + Quenching Lamp
2
Charge Corona + Standard Image Grid
3
Charge Corona + Standard ID Sensor Grid
5
Transfer Corona
6
Separation Corona
8
Erase Lamp
10
ID Sensor LED
11
Toner Supply Motor
12
Registration Clutch
13
Paper Feed Clutch
15
Relay Roller Clutch
17
Machine Shut Off
18
Exhaust Blower Motor
19
Optics Cooling Fan
20
Exposure Lamp + Optics Cooling Fan
21
Total Counter
30 ~ 37
Development Bias Voltage in 40-volt steps starting at –120 volts
38
Development Bias Voltage = –500 volts
40 ~ 48
Grid Voltage in 60-volt steps starting at –400 volts