2.3 CODE #13 — ZERO CROSS SIGNAL ERROR
- Definition -
The CPU does not receive the zero cross signal within 0.56 second.
- Possible Causes -
Defective main board
Defective dc power supply board
Zero cross line open
CN107 on the main board or CN202 on the dc power supply board is
not correctly connected.
- Action -
Turn the main switch off and on.
Check that CN107 on the main board and CN202 on the dc power supply
board are correctly connected.
Correct
Incorrect
Connect CN107 and CN202
Check the voltage at CN202-2 on the dc power supply board.
0.6 volt
0 volts
Replace the dc power supply board.
Check the voltage at CN107-1 on the main board.
0.6 volt
0 volts
Replace the dc harness.
Replace the main board.