2. Installation

Installation Requirements

Operating Environment

• Install in a location within the following environmental range.
Item
Temperature
Humidity
Maximum altitude
Power source
• Be sure not to keep in a place where there is a lot of humidity, oil mist, and dust.
• Be sure not to plug up any ventilating hole during installation.
• When moving, disconnect the power cord, VGA cable and network line.
• Be sure not to place this machine on other apparatus, or not to put other apparatus on this
machine.
• Be sure to connect the grounding terminal of the power plug with the ground, and be sure not to
use it in a place where ventilation is poor.
• Requirements for sharing a remote whiteboard
Port: Communication is possible with 61616 (ActiveMQ), 50000, 50001, and 50002.
Delay: 100 ms or less
Band: 200K bps or more (minimum guarantee), 500K bps or more (recommendation)

Minimum Space Requirements

Be sure to provide sufficient space for wiring of cables and ventilation.
10 to 32°C (50 to 89.6°F)
* When it is used with 60% to 80% humidity, the upper limit of the
guaranteed temperature falls by up to approximately 7°C (12.6°F).
15 to 80% (non-condensing)
2,000m (6,600 feet)
AC100V-240V, 50/60Hz
Environment
13