[B]
[A]
16. Place the dark silver wires ([1] and [3]) around the pulleys as shown.
17. Attach wire [3] to the rear wire fixing plate [A], then hook one end of
tension spring [B] to the fixing plate and the other end to the frame
projection.
18. Reinstall and tighten the first scanner clamps [C] (front and rear) and
remove the four positioning pins and the omega clamp.
19. Perform a free run (turn DIP switch 101-1 ON) to condition the wires.
A151/A152
[3]
[1]
[C]
5-18
[C]
SM