25. Check that the rubber pad [C] is in contact with the top of the operation
panel cover. If it is not, remove the DF grip [D] (2 screws), then adjust the
position of the magnet catch [E] so that the rubber pad is in contact with
the top of the operation panel cover.
26. Turn on the main switch and check the operation of the DF.
SM
[E]
[C]
A662I514.img
8-33
INSTALLATION
[D]
[E]
A662I515.img
A202/A203