7510-XXX
Step
4
Check the bridge unit diverter gate solenoid for proper
operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Finisher Motor Test.
4. Touch Bridge unit diverter gate solenoid.
Does the above component operate properly?
5
Check the bridge unit diverter gate solenoid for proper
connection.
Is the above component properly connected?
6
Check the bridge unit bin media exit solenoid for proper
operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Finisher Motor Test.
4. Touch Bridge unit bin media exit solenoid.
Does the above component operate properly?
7
Check the bridge unit bin media exit solenoid for proper
connection.
Is the above component properly connected?
2-16
MFP Finisher Service Manual
Check
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
Caution: When performing motor tests,
ensure that all cover and door interlock
switches are overridden.
Yes
Go to step 6.
Go to step 5
Replace the bridge
Replace the
unit diverter gate
connection.
solenoid.
Go to
"Bridge
unit diverter gate
solenoid
removal" on
page
4-14.
Go to step 8.
Go to step 7
Replace the bridge
Replace the
unit bin media exit
connection.
solenoid.
Go to
"Bridge
unit bin media
exit solenoid
removal" on
page
4-16.
No