Input Source Print Test; Print Quality Test Pages - Lexmark X940e Service Manual

Mfp finisher
Hide thumbs Also See for X940e:
Table of Contents

Advertisement

To run the Print Tests:
1. Touch PRINT TESTS from the Diagnostics Menu.
2. Touch [Input Source] to verify that the printer can generate output from that source's media.
3. Touch Printing Quality Test Pages to view information about the printer's current settings and to test the
printer's ability to generate quality output.
Input source
Tray 1
Tray 2
Tray 3
Tray 4
MP Feeder
Printing Quality Test Pages
4. Touch Single or Continuous.
If Single is selected, a single page is printed.
If Continuous is selected, printing continues until Stop
If a source is selected that contains envelopes, an envelope test pattern is printed. If Continuous is
selected, the test pattern is printed only on the first envelope.
After a Single test has printed or a Continuous test canceled, the LCD returns to the [Input Source] screen.

Input Source Print Test

Regardless of the input source selected, the printer always generates a simplex version of the Print Test page
using its default resolution.

Print Quality Test Pages

This setting enables you to view the values of a broad range of the device's settings and to test the device's
ability to generate acceptable printed output.
The printer automatically generates a Print Quality Test page in English and an:
1. Entire printable area of the page is solid dark blue
2. Entire printable area of the page is solid dark magenta
3. Entire printable area of the page is solid dark yellow
4. Entire printable area of the page is solid dark black
5. Entire printable area of the page is solid light blue
6. Entire printable area of the page is solid pink
7. Entire printable area of the page is solid light yellow
8. Entire printable area of the page is solid gray
The device always uses the media that is currently installed in Tray 1 to print this report. Once started, printing
cannot be canceled and all key presses are ignored until printing completes.
The test pages are always simplexed, regardless of the value of the duplex setting.
Appears on the LCD
Tray 1 Printing...
Tray 2 Printing...
Tray 3 Printing...
Tray 4 Printing...
MP Feeder Printing...
Printing Quality Test Pages...
is pressed to cancel the test.
Diagnostic aids
7510-XXX