Analyzing The Manual Scanner Registration Copies; Manually Adjusting The Scanner's Registration - Lexmark X940e Service Manual

Mfp finisher
Hide thumbs Also See for X940e:
Table of Contents

Advertisement

Analyzing the manual scanner registration copies

1. To analyze the manual scanner registration of the flatbed, ADF side 1, and ADF side 2, hold the test copy
according to the diagram below.
2. Compare the three copies to the registration test original page for image placement. Ideally, the image
should be centered on the page by measuring the paper edge arrows or the black lines with a ruler.
3. If the leading and side margin edges are out of adjustment, then proceed to manually adjust the scanner
and/or ADF side 1 and ADF side 2 registration.
Note: Margin tolerance is +/- 2 mm.

Manually adjusting the scanner's registration

1. Enter the Diagnostics Menu. Go to
2. Touch SCANNER TESTS.
3. Touch Scanner Manual Registration.
Note: Refer to analyzing the manual scanner registration copies. See
registration copies" on page
"Diagnostics Menu" on page
3-31.
3-1.
"Analyzing the manual scanner
Diagnostic aids
7510-XXX
3-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

X945e

Table of Contents