Melsecnet/10 Connection - Mitsubishi Electric GOT1000 Series Handbook

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

1. CONNECTION CONFIGURATION

4.1.7 MELSECNET/10 connection

System configuration
1) Optical loop
Target device
QCPU
QSCPU
QnA/ACPU
(control station/
normal station)
Motion controller
Optical fiber
*1*2
CPU(Q series)
Motion controller
CPU(A series)
*2
CNC C70
*2
CRnQ-700
A
J61QBT11
C
Network module
2) Coaxial bus
Target device
QCPU
QSCPU
QnA/ACPU
(control station/
normal station)
Motion controller
*1*2
CPU(Q series)
Coaxial
Motion controller
CPU(A series)
*2
CNC C70
*2
CRnQ-700
A
J61QBT11
C
Network module
*1: Not available for GT SoftGOT1000.
*2: Configure the multiple CPU system.
*3: For the cable type to be used, refer to th MELSECNET/H reference manual.
*4: Cannot be used on GT155
.
*5: Cannot be used when the GOT is connected to Q02UCPU, Q03UDCPU,
Q04UDHCPU, Q06UDHCPU, Q13UDHCPU, Q26UDHCPU, Q03UDECPU,
Q04UDEHCPU, Q06UDEHCPU, Q13UDEHCPU, Q26UDEHCPU,
Q172DCPU, Q173DCPU, CNC C70 or CRnQ-700.
*6: Distance between stations for using the QSI fiber-optic cable.
The overall extension cable length and the length between stations differ
depending on the cable type to be used and the total number of stations.
For details, refer to the MELSECNET/H and MELSECNET/10 reference manuals.
148
4.1 MITSUBISHI Programmable Controller
4.1.7 MELSECNET/10 connection
Cable
Communication unit
*8
MELSEC
NET/H
*4 *5
MELSEC
NET/10
GT15-75J71LP23-Z
*3
*8 *9
MELSEC
NET/H
board
Q80BD-J71LP21-25
Q80BD-J71LP21G
Programmable
controller CPU
Cable
Communication unit
MELSEC
NET/H
*4 *5
MELSEC
NET/10
GT15-75J71BR13-Z
*3
*8 *9
MELSEC
NET/H
board
Programmable
controller CPU
GT15-J71LP23-25
DOS/V personal
computer
GOT
PC CPU
MELSECNET/H
module
network module
QJ71LP21-25
RUN
MNG
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
X1
IN
4
MODE
Install to a PC
OUT
QJ71LP21
-25
CPU module.
*8
GT15-J71BR13
DOS/V personal
computer
Q80BD-J71BR11
GOT
PC CPU
MELSECNET/H
module
network module
QJ71LP21-25
RUN
MNG
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
X1
IN
4
MODE
Install to a PC
OUT
QJ71LP21
-25
CPU module.
*7 Connect the PC CPU module to another programmable controller.
*8: Select the MELSECNET/10 mode for [Communication Setting].
*9: When connecting to the Q redundant system, use the version K or later for the
MELSECNET/H board driver (SW0DNC-MNETH-B).
*10: Distance between stations for using the 5C-2V coaxial cable.
The overall extension cable length and the length between stations
differ depending on the cable type to be used and the total number of stations.
For details, refer to the MELSECNET/H reference manual.
GOT
Max. number of
GOTs connected
63
GT16/GT15
Max. connection
distance
1 km
GT15
Max. number of
personal computers
connected
64
GT SoftGOT1000
+
Max. connection
License key for
distance
GT SoftGOT1000
1 km
*7
Max. number of
personal computers
connected
64
GT SoftGOT1000
Max. connection
+
distance
License key for
GT SoftGOT1000
1 km
GOT
Max. number of
GOTs connected
31
GT16/GT15
Max. connection
distance
500 m
GT15
Max. number of
personal computers
connected
32
GT SoftGOT1000
Max. connection
+
distance
License key for
500 m
GT SoftGOT1000
Max. number of
*7
personal computers
connected
32
GT SoftGOT1000
Max. connection
+
distance
License key for
500 m
GT SoftGOT1000
*6
*6
*6
*10
*10
*10

Advertisement

Table of Contents
loading