Mitsubishi Electric GOT1000 Series Handbook page 25

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

Use your personal computer as a GOT
GT
SoftGOT1000
For GOT1000
Screen data created by GT Designer2 Version2 can be used without conversion.
GT SoftGOT1000 is an HMI software which offers the GOT1000 functions
on personal computers and panel computers.
Remote monitoring over the factory LAN
Conditions at the production sites can
be monitored from a remote location.
Multiple instances of GT
SoftGOT1000 can run on a
single personal computer.
Reduce cost by minimizing
the system recovery time.
Upon occurrence of problems, the status of on-site
equipment can be quickly monitored from your office.
This reduces the time for an initial diagnosis.
Office
Personal
computer
Worksite
Ethernet
Production site
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
Q61P-A1
POWER
RUN
MNG
RUN
MNG
Q61P-A1
POWER
RUN
MNG
RUN
MNG
MODE
RUN
T.PASS
SD
D.LINK
RD
T.PASS
SD
RD
D.LINK
MODE
RUN
T.PASS
SD
D.LINK
RD
T.PASS
SD
RD
D.LINK
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
USER
USER
BAT
BAT
BOOT
0
BOOT
0
1
1
2
2
3
3
4
4
PULL
5
PULL
5
6
6
7
7
8
8
USB
9
USB
9
A
A
B
B
C
C
D
D
PULL
E
PULL
E
F
F
Line 1
Line 2
Connection with MELSEC instrumentation
Now compatible with
GT SoftGOT1000 and PX Developer
the new process
monitoring tools can be connected to
control CPUs (Q02PH
easily establish an instrumentation
and Q06PHCPU).
monitoring system.
PX Developer face plate and other tools
Tools for monitoring, operating and tuning loop control tags.
(The display position can be specified.)
GT SoftGOT1000 (English version) operating environment
Item
With DOS/V personal computer
Personal computer
PC/AT compatible PC on which
Windows
®
2000, Windows
or Windows Vista
®
®
OS
Microsoft
Windows
Microsoft
®
Windows
®
Microsoft
®
Windows
®
®
®
Microsoft
Windows
®
Microsoft
Windows Vista
®
Microsoft
Windows Vista
®
Microsoft
Windows Vista
®
Microsoft
Windows Vista
®
Microsoft
Windows Vista
Other than Microsoft
CPU
Microsoft
®
Windows Vista
Required memory
Other than Microsoft
®
Microsoft
Windows Vista
*1
Free hard disk space
For installation (product only): 600MB or more
Disk drive
CD-ROM disk drive
65536 colors or more
Display colors
Display
Display usable on the above OS, which has a resolution of VGA (640 ´ 480 dots) or higher
When creating or editing project data
Software
When using with PX Developer
*6
Hardware
GT15-SGTKEY-U (License key
(for USB port))
GT15-SGTKEY-P (License key
(for parallel port))
Internet Explorer Ver. 5.0 or higher must be installed.
Other
Mouse, keyboard, printer and CD-ROM drive usable with the above OS
Version2
Monitoring Line 1 Monitoring Line 2
Monitoring Line 3
Monitoring Line 4
Personal
computer
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
Q61P-A1
POWER
RUN
MNG
RUN
MNG
Q61P-A1
POWER
RUN
MNG
RUN
MNG
MODE
RUN
T.PASS
SD
RD
D.LINK
T.PASS
SD
D.LINK
RD
MODE
RUN
T.PASS
SD
D.LINK
RD
T.PASS
SD
D.LINK
RD
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
USER
USER
BAT
BAT
BOOT
0
BOOT
0
1
1
2
2
3
3
4
4
PULL
5
PULL
5
6
6
7
7
8
8
USB
9
USB
9
A
A
B
B
C
C
D
D
PULL
E
PULL
E
F
F
Line 3
Line 4
Description
With PC CPU module
CONTEC PC CPU unit
®
XP,
(PPC-852-212, PPC-852-217,
®
operates.
PPC-852-226)
*7
2000 Professional Operating System Service Pack 4 or later (English version)
XP Professional Operating System Service Pack 2 or later (English version)
XP Home Edition Operating System Service Pack 2 or later (English version)
*3 *4 *8
XP Embedded Operating System (English version)
®
*3 *4 *9
Ultimate Operating System (English version)
®
*3 *4 *9
Enterprise Operating System (English version)
®
*3 *4 *9
Business Operating System (English version)
®
Home Premium Operating System (English version)
®
Home Basic Operating System (English version)
®
Windows Vista
®
: Pentium 2
®
300MHz or higher
®
: 800MHz or higher (recommended: 1GHz or more)
®
®
Windows Vista
: 128MB or more
®
: 512MB or more (recommended: 1GB or more)
: GT Designer2
: PX Developer Version 1.13P or later
GT Designer2 Version 2.45X or later
GT15-SGTKEY-U (License key
(for USB port))
Better linkage with other applications
and more flexibility when creating screens
Create a screen at a desired resolution depending on the applicable
space on the screen. This function is useful when simultaneously
displaying the GT SoftGOT1000 screen with another application
software program on a personal computer display.
(Screen size can be specified in the range of VGA to UXGA)
Full-screen display: The whole monitoring screen such as XGA can be
displayed in full-screen by hiding the title bar and the menu bar. Moreover,
the screen size can be freely changed from other applications.
Internal device interface functions: By using internal device interface functions,
user-created applications can read/write data from/to the GOT internal devices.
It is possible to link data to user applications such as a data logger in order to
develop advanced systems that can run in cooperation with applications.
<Development environment of user applications>
Microsoft
®
Visual C++.NET2003, Microsoft
Microsoft
®
Visual Basic.NET2003, Microsoft
Startup of other applications: In full-screen mode, other
applications can be started with touch switches on the
monitor screen of the GT SoftGOT1000.
Specification
Item
Resolution
(dots)
Display colors
*2 *4
Memory capacity
*3 *4 *9
Connection
*3 *4 *9
configuration
*1 :
Use of GT Designer2 and PX Developer requires additional vacant
*3 *4 *9
memory space. For these space requirements, refer to the GT Designer2
Version2 Basic Operation/Data Transfer Manual, and to the PX
*3 *4 *9
Developer Version1 Operation Manual (Monitor Tool). Additional memory
space is also required when using user-created applications.
*2 :
Administrator authority is required to install GT SoftGOT1000.
*3 :
Administrator authority is required to install and operate GT SoftGOT1000.
*4 :
The following functions are not supported.
• Compatible Mode
• Desktop Theme (Font) Change
*5 :
GT Designer2 and GT SoftGOT1000 must be installed from the same GT
Works2/GT Designer2.
*6 :
The PC must be equipped with a USB port to use the GT15-SGTKEY-U.
The PC must be equipped with a parallel port (Centro/printer connector)
to use the GT15-SGTKEY-P.
*5
*7 :
For CONTEC PC CPU unit, refer to the manual for the PC CPU module.
*8 :
Use is possible only when PPC-852-226 is preinstalled.
*9 :
Supported only by a 32-bit OS.
*10 :
The required devices vary depending on the connection configuration.
*11 :
Connectable only when using a PC CPU unit.
* :
Some functions are not operable on the GT SoftGOT1000.
For details, see "Functions list" (page 28, 29).
®
Visual C++ (Version.6.0),
®
Visual Basic (Version.6.0)
PX Developer monitoring tool bar
Clicking on buttons executes various operations
such as starting up the GT SoftGOT1000 and
switching base screens.
GT SoftGOT1000 base screen
Make your desktop into a graphic monitoring
window by displaying the GT SoftGOT1000
base screen in full-screen mode and sending
the window to the back of the screen.
GT SoftGOT1000 touch switch/object
Clicking on touch switches and objects displays
various screens of PX Developer monitoring
tools. (The display position can be specified.)
640 480, 800 600, 1024 768,
1280 1024, 1600 1200
Specifiable resolution (640 to
1600 480 to 1200)
65536 colors
57MB
Bus connection
*11
, CPU direct connection,
computer link connection,
*10
CC-Link IE controller network connection,
MELSECNET connection, Ethernet connection
• Fast User Switching
• Remote Desktop
1.1 Product Lineup
1
2
3
4
5
6
7
7

Advertisement

Table of Contents
loading

Table of Contents