Mitsubishi Electric GOT1000 Series Handbook page 107

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

1. CONNECTION CONFIGURATION
The GOT model to be used differs depending on the connection type.
Series
RS-232 or RS-422 connections
GT11
Bus connection
Handy GOT
RS-232 or RS-422 connections
Precautions
Other precautions
For the cable configuration of GT15-C
Use the GT15-QBUS(2) or GT15-ABUS(2) for mounting units for the multimedia function, printer function,
Video/RGB display, RGB output, Ethernet download, gateway function, and MES interface function, CF
card unit, and CF card extension unit.
The GT15-75QBUS(2)L and GT15-75ABUS(2)L are not available.
For GT16, however, Ethernet download, gateway function, and MES interface function are available using
the Ethernet interface.
When connecting multiple GOTs, the GOT1000 series, GOT-A900 series, GOT800 series and A77GOT
cannot be connected together.
For connecting the GOT to the multiple CPU system (Q00CPU, Q01CPU, Q02CPU, Q02HCPU,
Q06HCPU, Q12HCPU, and Q25HCPU), use CPUs with the function version B or later.
When connecting to Q00JCPU of MELSEC-Q series (Q mode)
When using the bus extension connector box, mount it on the extension base unit. (The bus extension
connector box cannot be mounted on the main base unit.)
When connecting to Q4ARCPU of MELSEC-QnA series (QnACPU type)
For the redundant Q4ARCPU system, connect the GOT to redundant extension base unit A68RB (version
B or later) at the last stage via the bus connection.
When connecting to A1SJCPU, A1SJCPU-S3, and A1SJHCPU of MELSEC-A series (AnSCPU type)
When using the extension base unit, the bus connection is disabled.
When connecting to motion controller CPU (Q series)
• For Q172CPU or Q173CPU
Use the motion controller CPU with the following production numbers.
Q172CPU with K******* or later, Q173CPU with J******* or later
• For Q172 or Q173CPU
For using the SV13, SV22, and SV43, use a motion controller with the following OS installed.
SW6RN-SV13Q
• For Q172CPUN or Q173CPUN
For using the SV13, SV22, and SV43, use a motion controller with the following OS installed.
SW6RN-SV13Q
When connecting to motion controller CPU (A series) (small-sized type)
When using the extension base unit, use the A168B.
For other precautions for the bus connection, refer to "Details of bus connection" in section 4.1.3.
Related Manuals
• For details of system configuration and
connection cable
• For precautions and restrictions
• For outlined procedure and checking of bus
connection
• For controllers that can be monitored by GOT and
accessible range
*
For restrictions and precautions on controllers connected to a GOT, refer to the manual for each controller.
Connection type
GT115
GT115
GT115
EXSS-1, refer to "External Dimensions" in section 1.5.
: 00E or later, SW6RN-SV22Q
: 00H or later, SW6RN-SV22Q
GOT model to be used
-Q
BD
-Q
BDQ, GT115
-Q
BDA
HS-Q
BD
: 00E or later, SW6RN-SV43Q
: 00H or later, SW6RN-SV43Q
Chapter 2 in GOT1000 Series Connection Manual (SH-
080532ENG)
Chapter 2 in GT Designer2 Version2 Screen Design
Manual (For GOT1000 Series) (SH-080530ENG)
4.1 MITSUBISHI Programmable Controller
4.1.2 Bus connection
1
2
3
4
5
: 00B or later
: 00B or later
6
7
89