1. CONNECTION CONFIGURATION
The GOT model to be used differs depending on the connection type.
Series
RS-232 or RS-422 connections
GT11
Bus connection
Handy GOT
RS-232 or RS-422 connections
RS-232 or RS-422 connections
GT105
RS-232 connection
GT10
GT1030
GT1020
RS-422 connection
Precautions
Precautions on setup
When connecting or disconnecting converter/cable for GT SoftGOT1000
• When connecting or disconnecting converter/cable that receives 5VDC power
When connecting or disconnecting the converter/cable that receives 5VDC power from a
programmable controller, power off the programmable controller and start working.
• When connecting or disconnecting converter/cable that does not receive 5VDC power
When connecting or disconnecting peripheral devices and the cables that do not receive 5VDC
power from a programmable controller (receives the power from an external power supply), follow
the procedure as below.
1) Be sure to use an earth band or touch a grounded metal object before working to discharge the
static electricity from the cables, human body, and others.
2) Power off the personal computer.
3) Power off the converter. When the converter/cable have an FG terminal, ground it.
4) Connect/disconnect the converter/cable between the personal computer and programmable
controller.
5) Power on the converter.
6) Power on the personal computer.
7) Start up the software package.
Related Manuals
• For details of system configuration and
connection cable
• For precautions and restrictions
• For outlined procedure and checking of direct
CPU connection
• For controllers that can be monitored by GOT and
accessible range
• For connection method with Handy GOT
• For connection method with GT SoftGOT1000
• For controllers that can be monitored by GT
SoftGOT1000 and accessible range
*
For restrictions and precautions on controllers connected to a GOT, refer to the manual for each controller.
126
4.1 MITSUBISHI Programmable Controller
4.1.4 Direct CPU connection
Connection type
GT115
GT115
GT115
GT105
GT1030-LBD2/GT1030-LBDW2, GT1020-LBD2/GT1020-LBDW2
GT1030-LBD/GT1030-LBDW, GT1020-LBD/GT1020-LBDW,
GT1020-LBL/GT1020-LBLW
(For GT1020-LBL/GT1020-LBLW, MELSEC-FXCPU connection is available only.)
GOT model to be used
-Q
BD
-Q
BDQ, GT115
-Q
BDA
HS-Q
BD
-Q
BD
Chapter 3 in GOT1000 Series Connection Manual (SH-
080532ENG)
Chapter 2 in GT Designer2 Version2 Screen Design
Manual (For GOT1000 Series) (SH-080530ENG)
Chapter 10 in Handy GOT User's Manual
(JY997D20101)
Chapter 2 in GT SoftGOT1000 Version2 Operating
Manual (SH-080602ENG)
Chapter 2 in GT Designer2 Version2 Screen Design
Manual (For GOT1000 Series) (SH-080530ENG)