Precautions
Precautions on system
When using cyclic transmission
(1) I/O signals from/to master station
Do not turn on reserved output signals among output signals from the master station to a GOT
(remote output: RY).
When the reserved output signals are turned on, MELDAS (C6/C64) may malfunction.
(2) CC-Link mode
The CNC is not applicable to the CC-Link network system Ver.2.
When using transient transmission
(1) Accessible range for monitoring
A GOT can access a programmable controller CPU with the CC-Link module set as the master or
local station. The GOT cannot access other networks via the CC-Link module.
Starting GOT with CC-Link connection (intelligent device station)
When the CC-Link connection (intelligent device station) is used, the data link starts in about 10 minutes
after starting the GOT.
Version of MELDAS C6/C64
For MELDAS C6/C64, use the NC system software version D0 or later.
Precautions on setup
When changing the switch setting after installing the GT15-75J61BT13-Z type CC-Link communication
unit on a GOT, reset the GOT.
Setting [Network parameters] of GX Developer
• When [Mode] of the CC-Link module is set to [Remote net (Ver.2 mode)], [Remote station points] can
be set. The [Remote station points] setting is a setting for the remote I/O station. For a GOT, use the
default value (32 points).
• Set the station information setting to [Ver.1 Intelligent device station] when [Mode] of the CC-Link
module is set to [Remote net (Ver.2 mode)] or [Remote net (Additional mode)].
Other precautions
When an error related to the network occurs as the system alarm
When an error related to the network occurs as the system alarm with the CC-Link connection (intelligent
device station), the displayed system alarm cannot be erased even though the error factor is removed.
Restart a GOT to erase the system alarm.
Related Manuals
• For details of system configuration and
connection cable
• For precautions and restrictions
• For outlined procedure and checking of CC-Link
connection
• For controllers that can be monitored by GOT and
accessible range
*
For restrictions and precautions on controllers connected to a GOT, refer to the manual for each controller.
Chapter 40 in GOT1000 Series Connection Manual