4.5.8 PF Encoder Sensor

Part/Unit that should be removed before removing PF Encoder Sensor
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit
Removal Procedure
1.
Peel off the acetate tape (x1) from the PF Encoder Sensor.
2.
Release the PF Encoder FFC from the connector (x1) of the PF Encoder Sensor.
3.
Remove the screw (x1) that secures the PF Encoder Sensor, and remove it.
PF Encoder Sensor
Figure 4-45. Removing PF Encoder Sensor
DISASSEMBLY/ASSEMBLY
PF Encoder FFC
Acetate Tape
C.B.P. 2.5x8, F/Zn-3C (4±1kgfcm)
Disassembling Printer Mechanism
When installing the PF Encoder Sensor, be sure to attach the
acetate tape (x1) referring to the figure below.
30mm
Figure 4-46. Acetate Tape Position
Revision B
Align here with edge of
the PF Encoder Sensor