3. Periodic check
3.3

Maintenance procedure

NOTE
• The alcohol referred to in the following procedures is isopropyl alcohol.
3.3.1

Paper feed roller

A. Cleaning procedure
[2]
2. Open the top cover.
See P.31
3. Remove the drum cartridge.
See P.16
10
1. Pull the lever [1] and swing open the
IR unit [2].
NOTE
• Note that the IR unit cannot be
swung up with the Auto Document
Feeder Unit in its raised position.
[1]
4139F2C514DA
NOTE
• Position the removed drum car-
tridge as shown in the illustration at
the left.
• Be sure to keep the drum cartridge
horizontal and place it where it will
not become dirty.
• Do not leave the drum cartridge
removed for more than 15 minutes,
and do not place the removed drum
cartridge in a location where it will
be exposed to direct light (such as
4139fs2538c0
sunlight).
Field Service Ver. 1.0 Aug. 2007