LIFTGATE LOCK MOTOR

REMOVAL

(1) Disconnect and isolate the battery negative
cable.
(2) Remove liftgate trim panel.
(3) Disconnect motor wire harness connector.
(4) Remove liftgate lock motor from liftgate (Fig. 1)
by gently unsnapping.
Fig. 1 Liftgate Lock Motor Location
1 - LIFTGATE CYLINDER LOCK SWITCH
2 - LIFTGATE LOCK MOTOR
3 - LATCH ASSEMBLY
4 - LIFTGATE AJAR SWITCH

INSTALLATION

(1) Install liftgate lock motor on the liftgate.
(2) Install motor wire harness connector.
(3) Install the liftgate trim panel.
(4) Connect the battery negative cable.
REMOTE KEYLESS ENTRY
MODULE
DIAGNOSIS AND TESTING - REMOTE KEYLESS
ENTRY MODULE
Refer to the appropriate wiring information. The
wiring information includes wiring diagrams, proper
wire and connector repair procedures, further details
on wire harness routing and retention, as well as
pin-out and location views for the various wire har-
ness connectors, splices and grounds. Refer to the
proper Body Diagnostic Procedures Manual for test-
ing the Remote Keyless Entry system using a DRB
III scan tool.
REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Remove the instrument panel top cover.
(3) Remove the two screws holding the RKE mod-
ule to the instrument panel assembly (Fig. 2).
Fig. 2 RKE Module Remove/Install
(4) Slide locking tab of the wiring connector side-
ways to unlock tab, and remove connector from RKE
module.
(5) Remove RKE module from vehicle.
NOTE: When replacing a faulty RKE Module, the
replacement module must be configured with the
DRB lll
scan tool for proper operation. Refer to
Vehicle Theft/Security Systems, Configuring a New
Module under Service Procedures. Additionally, all
transmitters must be reprogrammed to the new
RKE module.
INSTALLATION
(1) Install the RKE module on instrument panel.
(2) Connect the wiring harness connector to the
RKE module. Slide locking tab of the wiring connec-
tor sideways to lock tab.
(3) Install the two screws holding the RKE module
to the instrument panel assembly.
(4) Install the instrument panel top cover.
(5) Connect the battery negative cable.

POWER LOCKS