Dell 5535dn Service Manual page 125

Hide thumbs Also See for 5535dn:
Table of Contents

Advertisement

Error
code or
Error contents
message
925.00
Incorrect fuser or
fuser lamp detected.
Fuser type = 1
925.01
Incorrect fuser or
fuser lamp detected.
Fuser type = 1
925.02
Incorrect fuser or
fuser lamp detected.
Fuser type = 1
925.25
Incorrect fuser or
fuser lamp detected.
Fuser type = 2
925.26
Incorrect fuser or
fuser lamp detected.
Fuser type = 2
Description/Action
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
Possible repair actions
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to "Fuser unit
assembly removal" on
page 4-15.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to "Fuser unit
assembly removal" on
page 4-15.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to "Fuser unit
assembly removal" on
page 4-15.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to "Fuser unit
assembly removal" on
page 4-15.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to "Fuser unit
assembly removal" on
page 4-15.