Mazda RX-8 Workshop Manual page 484

2011 - rx-8
Hide thumbs Also See for RX-8:
Table of Contents

Advertisement

VERIFY FREEZE FRAME DATA (MODE 12)
1
AND DIAGNOSTIC MONITORING TEST
RESULTS HAVE BEEN RECORDED
Have the FREEZE FRAME DATA
(Mode 12) and DIAGNOSTIC
MONITORING TEST RESULTS
(EVAP system related) been
recorded?
VERIFY RELATED REPAIR INFORMATION
2
AVAILABILITY
Verify related Service Bulletins
and/or on-line repair information
availability.
Is any related repair information
available?
INSPECT EVAP SYSTEM LEAK DETECTION
3
PUMP
Inspect the EVAP system leak
detection pump.
(See
EVAPORATIVE EMISSION
(EVAP) SYSTEM LEAK DETECTION
PUMP INSPECTION
Is there any malfunction?
VERIFY TROUBLESHOOTING OF DTC P2407
4
COMPLETED
Make sure to reconnect all
disconnected connectors.
Clear the DTC from the PCM
memory using the M-MDS.
(See
AFTER REPAIR PROCEDURE
[13B-MSP].)
Perform the evaporative system
test using the M-MDS.
(See
ENGINE CONTROL SYSTEM
OPERATION INSPECTION [13B-
MSP].)
Is the same DTC present?
NOTE:
[13B-MSP].)
If the evaporative
system test
function is not
YesGo to the next step.
No Record the FREEZE FRAME DATA (Mode 12)
and DIAGNOSTIC MONITORING TEST
RESULTS on the repair order, then go to the
next step.
YesPerform repair or diagnosis according to the
available repair information.
If the vehicle is not repaired,
go to the next step.
No Go to the next step.
YesReplace the EVAP system leak detection
pump, then go to the next step.
(See
EVAPORATIVE EMISSION (EVAP)
CONTROL SYSTEM REMOVAL/INSTALLATION
[13B-MSP].)
No Go to the next step.
YesReplace the PCM, then go to the next step.
(See
PCM REMOVAL/INSTALLATION [13B-
MSP].)
No Go to the next step.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2011 rx-8