Mazda RX-8 Workshop Manual page 474

2011 - rx-8
Hide thumbs Also See for RX-8:
Table of Contents

Advertisement

Diagnostic procedure
STEP
VERIFY FREEZE FRAME DATA (MODE 12) AND
1
DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN
RECORDED
Have the FREEZE FRAME DATA (Mode 12) and
DIAGNOSTIC MONITORING TEST RESULTS
(EVAP system related) been recorded?
VERIFY RELATED REPAIR INFORMATION AVAILABILITY
2
Verify related Service Bulletins and/or on-line
repair information availability.
Is any related repair information available?
INSPECT EVAP SYSTEM LEAK DETECTION PUMP
3
CONNECTOR FOR POOR CONNECTION
Turn the ignition switch off.
Disconnect the EVAP system leak detection pump
connector.
Inspect for poor connection (such as
damaged/pulled-out pins, corrosion).
INSPECTION
YesGo to the next step.
No Record the FREEZE FRAME DATA (Mode 12) and
DIAGNOSTIC MONITORING TEST RESULTS on the repair
order, then go to the next step.
YesPerform repair or diagnosis according to the available repair
information.
If the vehicle is not repaired, go to the next
step.
No Go to the next step.
YesRepair or replace the connector and/or terminals, then go to
Step 7.
No Go to the next step.
ACTION