Command
IP Setup Commands (continued)
Bidirectional Serial Port (continued)
Configure flow control
24
View flow control
Configure receive timeout
24
View receive timeout
Send data string (web
encoding only)
X1&
X1* X5^
NOTE:
The
*
X1&
NOTE:
= Receive timeout
X1*
= Interval between characters
X4^
= Serial port number
X5@
= Flow control
X5#
= Data pacing
X5%
= Command data (for web encoding) Data is directed to the specified port and must be encoded as follows
X5^
= Command length or delimiter
X6*
= Message length or delimiter
X6(
= Priority status for receive timeouts
ASCII Command
(Host to Switcher)
E X4^
X5@
X5#
}
*
,
CF
E X4^
}
CF
E X4^
X1&
X1*
X6(
*
*
*
E X4^
}
CE
E X4^
X1&
X1*
X5^
*
*
*
X1&
sequence is optional. If
and
Time in tens of ms to wait for characters to arrive at the serial port
before terminating the connection. Default = 10 (100 ms).
Maximum = 32,767.
Time in tens of ms to wait between characters coming into the serial
port before terminating the connection. Default = 2 (20 ms).
Maximum = 32,767.
01 = RS232/RS422 port on rear panel, 02 = front panel Config port
H = hardware, S = software, N = none
Number of milliseconds between bytes (0000 – 1000). Default is 0.
if it is not alphanumeric:
Space (hex 20) should be encoded as %20 (hex 25 32 30)
Plus sign (hex 2B) should be encoded as %2B (hex 25 32 42)
Parameter to set either the length of the message to be received or a
delimiter value. Parameter is case-sensitive—it must be uppercase.
# is the
#L = length of the command to be received: 0
#D = delimiter value: 0 through 00255. The default is the byte
Parameter to set either the length of the message to be received or a
delimiter value. Parameter is case-sensitive—it must be uppercase.
L = length in bytes. Min = 0, max = 32767. Default is 0L (0 bytes).
D = decimal value for ASCII character (delimiter). Min = 0,
max = 00255. Default is 00000L.
Value precedes parameter; for example, 3-byte length = 3L.
0 = Use Send data string command parameters.
1 = Use configure receive timeout command parameters.
Default is 0.
HDXP Plus Series Switchers • Remote Configuration and Control
Response
(Switcher to Host)
X4^
X5@
X5# ]
Cpn
• Cfl
,
X5@
X5# ]
,
X6*
}
*
CE
X4^
X1&
X1* ]
Cpn
• Cce
,
X1&
X1*
X6(
X6* ]
,
,
,
} X5%
RS
Response to command
X1*
are not specified, the default values are used.
L
byte count for
or a single ASCII character in decimal format for
The default is 0. Example: A 3-byte length = 3L.
count.
Additional Description
X5@
Set flow control
and data
X5#
X4^
pacing rate
for port
.
X5#
View data rate
for flow
X5@
X4^
control
for port
.
Set receive timeout
X4^
parameters for port
:
X1&
Timeout after
ms for
arriving characters
X1*
Timeout after
ms
between characters
Message length or delimiter
X6*
value
.
X6(
Receive priority status
.
View the receive timeout
parameters.
X5%
Send command data
to
X4^
port
.
D
.
32767.
through
64