Command
Output Reclocking
Set the output reclocker
View the reclocker status
Example:
I/O Grouping
All input and output positions must contain a group number or 0. For example, for the HDXP 3216 or 3232, you
NOTE:
must enter 32 group numbers between
or output, enter 0 in its position.
Write input grouping
Example: HDXP 3232 or
HDXP 3216
Response #s = group:
Write output grouping
Read input grouping
Example: HDXP 1616
Read output grouping
X#
= Output number
NOTE:
X%
= Output reclocking rate
X1)
= Group number for I/O grouping
ASCII Command
(Host to Switcher)
X#
X%
*
=
X#
=
8 * 07 =
E
and I or between
E X1) X1)
X1)
}
...
n
I
E
}
401...3I
Input 1 in group 4
Input 2 not grouped
4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3
GrI
Input:
01
02 03 04 05 06 07 08 09 10 11 12
E X1) X1)
X1)
}
...
n
O
E
}
I
E
}
I
E
}
O
1 – maximum number of outputs for your model
00 = auto (default), 01 = bypass, 02 = 143 (component NTSC)
03 = 177 (component PAL), 04 = 270, 05 = 360, 06 = 540,
07 = 1485, 08 = 2970
0 – 4. 0 = not grouped.
HDXP Plus Series Switchers • Remote Configuration and Control
Response
Additional Description
(Switcher to Host)
X#
X% ]
Set the reclocking rate for
Rte
*
output
X% ]
Show current reclocking rate
X%
X#
X% ]
Verbose mode 2 or 3
Rte
*
]
The reclocking rate for output
Rte 08 * 07
8 is 1485.
E
and O. If you do not want to group a particular input
X1) X1)
X1)
]
Gri
...
n
Each
number assigned to an input
position, starting from input 1.
n = the maximum number of
inputs for this model.
See below.
Input 1 – group 4
input 2 – group 0 (ungrouped)
...
input 32 – group 3
13 14 15 16 17 18 19 20 21 22 23 24
X1) X1)
X1)
]
Gro
...
n
Each
number assigned to an output
position, starting from output 1.
n = the maximum number of
outputs for this model.
X1) X1)
X1)
]
...
n
Each
number assigned to an input
position, starting from input 1.
n = the maximum number of
inputs for this model.
Input 1 in group 1
Input 9 not grouped
1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2
Response = group:
Input:
01
02 03 04 05 06 07 08 09 10 11 12
X1) X1)
X1)
]
n
Each
...
number assigned to an output
position, starting at output 1.
n = the maximum number of
outputs for this model.
X#
X%
to
.
X#
for output
.
X1)
entry is the group
Input 32 in group 3
2 1 2 2 3 3 3 3
25 26 27 28 29 30 31 32
X1)
entry is the group
X1)
entry is the group
Input 16 in group 2
13 14 15 16
X1)
entry is the group