Removing The High-Speed Sas Adapter, The Adapter Cable, And The Solid-State Drive (Ssd); High-Speed Sas Adapter Assembly Mounted In The Back Rail Of The San Volume Controller - IBM SAN Volume Controller Hardware Maintenance Manual

System storage san volume controller
Table of Contents

Advertisement

Figure 191. High-speed SAS adapter assembly mounted in the back rail of the SAN Volume Controller 2145-CF8
5. Make sure that all cables, adapters, and other components are installed and seated correctly and that
you have not left loose tools or parts inside the node. Make sure that all internal cables are correctly
routed. If you disconnected the fibre-channel and Ethernet cables, make sure that each cable is
reconnected to the same port from which it was removed.
6. Replace the top cover. See "Replacing the top cover" on page 72.
After following the procedure to replace the top cover, the node is installed in the rack and is turned
on.
Removing the high-speed SAS adapter, the adapter cable, and the
solid-state drive (SSD)
You can remove the high-speed adapter assembly, the adapter cable, and the serial attached SCSI (SAS)
solid-state drives (SSDs) in the SAN Volume Controller 2145-CF8.
Removing the SAN Volume Controller 2145-CF8 high-speed SAS cable
You can remove the SAN Volume Controller 2145-CF8 high-speed SAS cable.
DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
This service action requires you to remove the cover and:
v Turn the node off.
v Disconnect the power cables.
v Disconnect the data cables.
To remove the SAN Volume Controller 2145-CF8 high-speed SAS adapter cable, perform the following
steps :
1. Read the safety information to which "Preparing to remove and replace parts" on page 20 refers.
2. Follow the procedure in MAP 5350 in the IBM System Storage SAN Volume Controller 2145
Troubleshooting Guide to verify that the node data is mirrored and synchronized, and that there are no
dependent volumes before turning off the node.
3. Slide the node out on its slide rails to the fully extended position.
4. When the node is completely turned off, remove the cable-retention brackets and disconnect the
power cables, as described in "Removing the cable-retention bracket" on page 29.
5. To make sure that you can replace all cables in the same ports from which they were removed, label
the port position of each fibre-channel and Ethernet cable; then remove all cables from the back of
the node.
6. Optional: Remove the node from the rack and place it on a flat, static-protective surface. See
"Removing the SAN Volume Controller from a rack" on page 40.
You can perform most service actions when the node is fully extended from the rack on its slide
rails. If the location of the node in the rack is too high or too low to work comfortably, you can
remove the node from the rack.