Intermec EasyCoder 501 XP Installation & Operation Manual page 71

Bar code label printer
Hide thumbs Also See for EasyCoder 501 XP:
Table of Contents

Advertisement

Chapter 8 Setup Mode
Setup Mode Overview, Part 3
(Intermec Fingerprint 7.31)
If an optional Double Serial or Industrial Interface Board is fitted, additional menus will be displayed
(in case of Double Serial Interface Board, also see Overview Part 4):
SETUP:
SER-COM,UART2
SETUP:
SER-COM,UART3
70
SER-COM,UART2:
BAUDRATE
SER-COM,UART2:
PROT ADDR
SER-COM,UART2:
CHAR LENGTH
SER-COM,UART2:
PARITY
SER-COM,UART2:
STOP BITS
SER-COM,UART2:
FLOWCONTROL
SER-COM,UART2:
NEW LINE
SER-COM,UART2:
REC BUF
SER-COM,UART2:
TRANS BUF
SER-COM,UART2:
CONNECTED HW
SER-COM,UART2:
PROTOCOL ADDR.
BAUDRATE:
9600
19200
38400
57600
300
600
1200
2400
4800
These menus are only displayed if RS 485 is selected on "uart2:"
PROT ADDR:
DISABLE
ENABLE
These menus are not displayed if RS 485 is selected on "uart2:"
CHAR LENGTH:
8
7
PARITY:
NONE
EVEN
ODD
MARK
SPACE
STOPBITS:
1
2
FLOWCONTROL:
RTS/CTS
FLOWCONTROL:
ENQ/ACK
FLOWCONTROL:
XON/XOFF
NEW LINE:
CR/LF
LF
CR
REC BUF:
[300]:
TRANS BUF:
The selected type of hardware connection on "uart2:"
[300]:
is displayed as one of the following alternatives (read-only):
• RS232
CONNECTED HW:
• 422 NON ISOLATED
RS232
• 422 ISOLATED
• RS485
PROTOCOL ADDR.
These menus are only displayed if RS 485 is selected on "uart2:"
Enter printer's protocol address (0–31).
[1]:
Intermec EasyCoder 501 XP – Installation & Operation Ed. 4
RTS/CTS flowcontrol cannot be
RTS/CTS:
selected for the following types of
DISABLE
hardware connection on "uart2:":
ENABLE
• 422 NON ISOLATED
• 422 ISOLATED
ENQ/ACK:
DISABLE
ENABLE
XON/XOFF:
DATA TO HOST
XON/XOFF:
DATA FROM HOST
DATA TO HOST:
DISABLE
ENABLE
DATA FROM HOST:
DISABLE
ENABLE

Advertisement