4.2.2 Configuring GARP Timers
Follow these steps to configure GARP timers:
Enter system view
Configure the GARP
LeaveAll timer
Enter
Ethernet
port view
or
port-group
view
Configure the hold
timer, join timer, and
leave timer
As for the GARP timers, note that:
The setting of each timer must be a multiple of five (in centiseconds).
The settings of the timers are correlated. If you fail to set a timer to a certain value,
you can try to adjust the settings of the rest timers.
relationship of the timers.
Table 4-2 Dependencies of GARP timers
Timer
Hold
Join
Leave
LeaveAll
To do...
Use the command...
system-view
garp timer leaveall
timer-value
Enter
interface interface-type
Ethernet
interface-number
port view
Enter
port-group { manual
port-group
port-group-name |
view
aggregation agg-id }
garp timer { hold | join |
leave } timer-value
10 centiseconds
Not less than two times the hold
timer setting
Greater than two times the join timer
setting
Greater than the leave timer setting
Lower limit
4-6
Chapter 4 GVRP Configuration
Remarks
––
Optional
The default is 1000
centiseconds.
Required
Perform either of the
operations.
Depending on the view you
accessed, the subsequent
configuration takes effect on
a port or all ports in a
port-group.
Optional
The default is 10
centiseconds for the hold
timer, 20 centiseconds for
the join timer, and 60
centiseconds for the leave
timer.
Table 4-2
shows the
Upper limit
Not greater than half of
the join timer setting
Less than half of the leave
timer setting
Less than the LeaveAll
timer setting
32765 centiseconds