H3C S7500E Series Operation Manual page 130

S7500e series
Hide thumbs Also See for H3C S7500E Series:
Table of Contents

Advertisement

Operation Manual – IP Addressing and Performance
H3C S7500E Series Ethernet Switches
PING 172.16.1.2: 56
Reply from 172.16.1.2: bytes=56 Sequence=1 ttl=255 time=25 ms
Reply from 172.16.1.2: bytes=56 Sequence=2 ttl=255 time=27 ms
Reply from 172.16.1.2: bytes=56 Sequence=3 ttl=255 time=26 ms
Reply from 172.16.1.2: bytes=56 Sequence=4 ttl=255 time=26 ms
Reply from 172.16.1.2: bytes=56 Sequence=5 ttl=255 time=26 ms
--- 172.16.1.2 ping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 25/26/27 ms
The information shown above indicates the switch can communicate with the hosts on
the subnet 172.16.1.0/24.
# Use the ping command to verify the connectivity between the switch and the hosts on
the subnet 172.16.2.0/24.
<Switch> ping 172.16.2.2
PING 172.16.2.2: 56
Reply from 172.16.2.2: bytes=56 Sequence=1 ttl=255 time=25 ms
Reply from 172.16.2.2: bytes=56 Sequence=2 ttl=255 time=26 ms
Reply from 172.16.2.2: bytes=56 Sequence=3 ttl=255 time=26 ms
Reply from 172.16.2.2: bytes=56 Sequence=4 ttl=255 time=26 ms
Reply from 172.16.2.2: bytes=56 Sequence=5 ttl=255 time=26 ms
--- 172.16.2.2 ping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss
round-trip min/avg/max = 25/25/26 ms
The information shown above indicates the switch can communicate with the hosts on
the subnet 172.16.2.0/24.
# Use the ping command to verify the connectivity between hosts on the subnet
172.16.1.0/24 and hosts on subnet 172.16.2.0/24. Ping Host B on Host A to verify that
the ping operation is successful.
data bytes, press CTRL_C to break
data bytes, press CTRL_C to break
1-6
Chapter 1 IP Addressing Configuration

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S7502eS7503eS7506eS7510eS7506e-v

Table of Contents