8.2.3 Failure to Access the Scanner using a Web Browser, Admin Tool,
or Central Admin Server
If access is not possible when attempting to connect to the scanner using a Web browser
or the Admin Tool, or when attempting to connect to the Central Admin Server from the
Central Admin Console, try the following steps:
Same as in
391).
■ Action
Check if a network connection is possible by trying the same solution for
Server Using Its IP Address" (page
The DNS server or WINS server is not functioning normally, or the
scanner name has not been registered in the DNS or WINS server.
■ Action
Check the connectivity of the specified IP address.
If it is possible to connect the scanner using the Admin Tool with a specified IP address, specify
the scanner's IP address in the DNS or WINS server.
Check the DNS or WINS server settings for the Web browser and the Admin Tool.
A misconfigured firewall between the computer installed with the Admin
Tool or Web browser and the scanner is denying access.
■ Action
If there is a firewall between the computer installed with the Admin Tool or Web browser and the
scanner, check that its settings are not preventing access.
The URL of the target scanner is not registered as a trusted site.
■ Action
Set the scanner URL as a trusted site for the Web browser.
1. In Internet Explorer, select the [Tools] menu
2. On the [Security] tab, select [Trusted sites] and press the [Sites] button.
3. Enter the URL of the scanner in the [Add this website to the zone] field, and press the [Add] button.
"Failure to Connect to a Server Using Its IP Address" (page