Calculating 3Db Bandwidth Of Mm200 Modulated Carrier; Input Level - Radyne MM200 Installation And Operation Manual

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
This section is not yet complete.

3.3 Calculating 3dB Bandwidth of MM200 Modulated Carrier

1.
Find the combined interface data rate:
DR
= Interface 1 Data Rate + Interface 2 Data Rate + Interface 3 Data Rate + Interface 4
C
Data Rate
2.
Find the Total Data Rate plus R/S mux overhead, and guard band overhead:
DR
= DR
x (204/184) x 1.001
T
C
3.
Find Channel Baud Rate:
BR
= DR
/(QAM x N
C
T
Where N
= number of channels (one to four)
C
and QAM = 2 for 4 QAM
4 for 16 QAM
5 for 32 QAM
6 for 64 QAM
7 for 128 QAM
8 for 256 QAM
4.
Select Channel Spacing:
C
= from 1.1 to 1.5 times channel baud rate.
S
This number is usually 1.25 but may be set anywhere within the range of 1.1 to 1.5.
5.
Total 3 dB bandwidth = BR

3.4 Input Level

Each IF channel has an independent dynamic range of 15 - 20 dB. This allows greater
performance during frequency selective fades. For normal operation, the MM200 was designed
to work with radios that have automatic gain control (AGC). The radio AGC will generally use the
average power of all the IF channels to set its power unlike the MM200 that independently AGCs
on each IF channel. When setting up the input level to the MM200, use the following procedure.
1.
If the Radio has a IF output level setting, adjust to the manufactures optimum point. If
there is none, set between 0 and –10 dBm.
2.
Verify that the input to the radio is not experiencing frequency selective fading or a deep
flat fade.
3.
Set the MM200 Demodulator attenuator (in the Demod menu) so that the AGC level
display reads approximately 340 (in the Monitor, Demodulator Menu). When multiple IF
channels exist there will be differences in AGC from channel to channel. These should
only be of concern if any channel exceeds 300 or is lower than 400. The AGC display
displays the value the M&C has assigned to the channel.
This display is un-calibrated and has a useful range of approximately 300 to 655. The number is
inversely proportional to the incoming signal (a higher number indicates a lower incoming signal).
TM086 - Rev. 4.1
)
C
x C
x (N
– 1) + BR
C
S
C
Theory of Operation