Sign In
Upload
Manuals
Brands
Radyne Manuals
Modem
DMD20 LBST
Radyne DMD20 LBST Manuals
Manuals and User Guides for Radyne DMD20 LBST. We have
3
Radyne DMD20 LBST manuals available for free PDF download: Installation And Operation Manual
Radyne DMD20 LBST Installation And Operation Manual (306 pages)
Universal Satellite Modem
Brand:
Radyne
| Category:
Modem
| Size: 7 MB
Table of Contents
Specifications
5
Installation and Operation Manual
37
Table of Contents
39
About this Manual
49
Related Documents
49
Safety Compliance
50
Limitations of Warranty
51
Customer Support
52
Chapter 1. Introduction
53
Overview
53
Configurations
54
Features/Options Installed at Time of Order
54
Feature Upgrades
54
Hardware Options
54
Factory Installed Options
55
Function Accessibility
55
Chapter 2. Installation
57
Unpacking and Inspection
57
Installation Requirements
58
Removal and Assembly
59
Mounting Considerations
59
Initial Configuration Check
60
Modulator Checkout
62
Initial Power-Up
62
Factory Terminal Setup
62
Chapter 3. Theory of Operation
63
Modem Hardware
63
L-Band/If Printed Circuit Card
64
Baseband Processing Printed Circuit Card
65
Enhanced Interface Printed Circuit Card
65
Functional Block Diagram
65
Front Panel
66
Baseband Processing
66
Tx Baseband Processing
67
Rx Baseband Processing
67
Monitor & Control (M&C) Subsystem
67
Terminal Port
68
Modem Remote Communications (RLLP)
68
Ethernet M&C Port
68
Modem Monitor Status
69
Async Port / ES-ES Communications
69
Internal Clock
69
Loopback Features (Terrestrial & IF)
70
Clocking Options
73
TX Clock Options
73
SCTE: Serial Clock Transmit External
74
SCT: Serial Clock Transmit
74
RX Buffer Clock Options
74
RX SAT Clock
75
CTE: Serial Clock Transmit External
75
SCT: Serial Clock Transmit
75
EXT CLK/EXT BNC: External Clock, J16
75
EXT IDI: Insert Data in
75
EXT REF: External Reference, Top BNC Port, J10
76
RS530/422/V.35 Interface (Standard)
76
Interface (Optional)
76
HSSI Interface (Optional)
76
Ethernet Data Interface (Optional)
76
Reed-Solomon Codec
77
Reed-Solomon Operation
77
Reed-Solomon Code Rate
77
Interleaving
78
Asynchronous Overhead Operation (Framing/Multiplexer Capability)
79
Standard IBS Mode
80
Asynchronous Multiplexer Mode
81
ESC Backward Alarms
81
To Disable the ESC Backward Alarms
81
Satellite Control Channel (SCC)
81
SCC Framing Structure
82
Aggregate Data Rate
83
Overhead Rate Comparison
83
Actual Overhead Rate Calculation
84
SCC Overhead Channel Setup
85
Doubletalk Carrier-In-Carrier Option
87
What Is Doubletalk Carrier-In-Carrier
87
Application Requirements
87
Operational Recommendations
90
System Functionality and Operational Considerations
91
Doubletalk Carrier-In-Carrier Cancellation Process
93
Margin Requirements
95
Carrier-In-Carrier Latency
95
Carrier-In-Carrier Link Design
95
Symmetric Data Rate Link
96
Asymmetric Data Rate Link
99
Power Limited Links
100
Carrier-In-Carrier Commissioning and Deployment
101
Validating Carrier-In-Carrier Performance
102
Operational References
103
Carrier-In-Carrier Link Budget Calculation
103
Estimating PSD Ratio
104
Estimating PSD Ratio from LST
104
Estimating PSD Ratio from Satmaster
105
Estimating PSD Ratio Using Spectrum Analyzer
105
Glossary
106
Doubletalk Carrier-In-Carrier Specifications
106
Carrier-In-Carrier Summary
106
EDMAC Satellite Framing/Deframing Mode
108
Locating the ID Code Operational Procedure
108
Strap Codes
108
Chapter 4. User Interfaces
109
User Interfaces
109
Front Panel User Interface
109
LCD Front Panel Display
111
Cursor Control Arrow Keys
111
Numeric Keypad
111
Front Panel LED Indicators
112
Parameter Setup
112
Front Panel Control Screen Menus
113
Main Menus
113
Modulator Menu Options and Parameters
114
Demodulator Menu Options and Parameters
123
Interface Menu Options and Parameters
128
Monitor Menu Options and Parameters
133
Alarms Menu Options and Parameters
136
System Menu Options and Parameters
144
Test Menu Options and Parameters
153
Terminal Mode Control
155
Modem Terminal Mode Control
155
Modem Setup for Terminal Mode
155
Terminal Port User Interface
156
Connecting the Terminal
156
Terminal Screens
156
Chapter 5. Rear Panel Interfaces
157
DMD20/DMD20 LBST Connections
157
Compact Flash
160
Power Input Modules
160
AC Power Input Module
160
DMD20 Chassis Connections (Standard)
160
Ext Ref (J10)
160
Tx if (J11)
160
TX L-Band if (J12)
160
Rx if
161
RX L-Band if
161
Alarm (J15)
161
Ext Clk (J16)
162
Async (J17)
162
J18
162
J19)
163
Remote (J20)
164
Ethernet (J21)
164
DMD20 LBST Chassis Connections (Standard)
165
Ext Ref (J10)
165
Tx (J11)
165
Rx (J14)
165
Alarm (J15)
165
Ext Clk (J16)
166
Async (J17)
166
J18)
166
J19)
167
Remote (J20)
168
Ethernet (J21)
168
DMD20/DMD20 LBST Optional Data Interfaces
168
IDR/IBS Interface (Optional)
169
Esc Alarm (J1)
169
Audio (J2)
170
Data (J3)
171
Bal (J4)
172
Switch Interface (J5)
173
Sd (DDI) (J6)
176
Ddo (J7)
176
IDI (J8)
176
Sd (Ido) (J9)
176
Ethernet Data Interface (Optional)
176
High-Speed Serial Interface (HSSI) (Optional)
177
Hssi (J6)
177
ASI/DVB/M2P Interface (Optional)
177
Asi in (J1)
177
Asi out (J2)
177
Dvb/M2P in (J3)
178
Dvb/M2P out (J4)
180
Ethernet Data Interface (Optional)
182
Audio (J2)
183
Data (J3)
184
Bal (J4)
184
Esc Alarm (J5)
185
Sd (DDI) (J6)
185
Ddo (J7)
185
IDI (J8)
185
Sd (Ido) (J9)
186
HSSI / Ethernet (J1)
186
Ethernet Data Interface
187
Gige Interface
188
Chapter 6. Maintenance and Troubleshooting
189
Periodic Maintenance
189
Clock Adjustment
189
Troubleshooting
189
Alarm Faults
190
Major Tx Alarms
190
Major Rx Alarms
191
Minor Tx Alarms
191
Minor Rx Alarms
192
Drop and Insert Alarms
193
Common Major Alarms
193
Alarm Masks
194
Active Alarms
194
Major Alarms
194
Minor Alarms
194
Common Equipment Faults
194
Latched Alarms
195
Backward Alarms
195
IBS Fault Conditions and Actions
195
Chapter 7. Technical Specifications
197
Data Rates
197
Modulator
197
Demodulator
198
Plesiochronous Buffer
199
Monitor and Control
199
DMD20/DMD20 LBST Drop and Insert (Optional)
199
Terrestrial Interfaces
199
IDR/ESC Interface (Optional)
199
Ibs/Synchronous Interface (Standard)
199
High-Speed Serial Interface (HSSI)
200
Asi
200
Dvb/M2P
200
Ethernet Data Interface (Optional)
200
Gigi Ethernet Data Interface (Optional)
200
Hssi / G703
200
Hssi /Ethernet
200
Environmental
201
Physical
201
DMD20/DMD20 LBST Data Rate Limits
201
Non-DVB
201
Dvb
203
BER Specifications
205
BER Performance (Viterbi)
205
BER Performance (Sequential)
206
BER Performance (Viterbi with Reed-Solomon)
207
BER Performance ((O)QPSK Turbo)
208
BER Performance (B/O/QPSK Turbo)
209
BER Performance (8PSK Turbo)
210
BER Performance (8PSK Trellis)
211
BER Performance (8PSK Turbo)
212
BER Performance (16QAM Viterbi)
213
BER Performance (16QAM Viterbi with Reed-Solomon)
214
BER Performance (16QAM Turbo)
215
BER Performance (16QAM Turbo)
216
1/2 Rate B/O/QPSK BER Performance (LDPC)
217
2/3 Rate Q/8PSK/8QAM BER Performance (LDPC)
218
3/4 Rate Q/8PSK, 8/16QAM BER Performance (LDPC)
219
AGC Output Voltage
224
Appendix A. Product Options
227
Hardware Options
227
G.703/IDR ESC Interface
227
Internal High Stability
227
DC Input Prime Power
227
ASI/RS-422 Parallel
227
ASI/LVDS Parallel
227
Hssi
227
Ethernet Data Interface
227
Gigi Ethernet Data Interface
228
Hssi
228
Hssi / Ethernet
228
Turbo Product Code / Variable Reed-Solomon
228
Combination Low-Density Parity Check (LDPC) and TPC Codec
228
Customized Options
228
Appendix B. Front Panel Upgrade Procedure
229
Introduction
229
Required Equipment
229
Upgrade Procedure
229
Demonstration Procedure
231
Running in Demonstration Mode
233
Canceling Demonstration Mode
234
Appendix C. Carrier Control
235
States
235
Carrier off
235
Carrier on
235
Carrier Auto
235
Carrier Vsat
236
Carrier RTS
236
Appendix D. Strap Codes
237
Strap Codes
237
Sample Applications
241
Operational Case Examples
242
Appendix E. Tcp/Ip Ethernet Setup
247
Introduction
247
TCP/IP Network Configuration
247
Network Configuration Summary
249
Ethernet Test
249
Connecting the Modem Ethernet Cable to a Network Link
249
Connecting the Modem Ethernet Cable Directly to a Computer (Without a Network
249
Testing the Ethernet Connection Using the Ping Program (Optional
252
Setup
253
TCP-IP Menus
253
IP Address
254
Appendix F. Web Interface Setup Guide
253
Introduction
253
Web Interface Security
254
Default User Accounts
254
User Account Data
255
User Account Setup
255
Edit the User ID
256
Edit the Access Group
256
Edit the Authentication Password
256
Reset a User Account
257
Confirmation
257
Equipment Website
258
Log in to the Equipment Website
259
Configure Web Browsers for the Radyne WEB Interface
261
Configure Internet Explorer 9 for the Radyne WEB Interface
261
Configure Firefox for the Radyne WEB Interface
261
Change the Encoding
262
Install the Internet Explorer Tab V2 Add-On
263
Configure Chrome for the Radyne WEB Browser
264
Change the Encoding
265
Install the Internet Explorer Tab for Chrome
266
Configure Safari for the Radyne WEB Browser
267
Empty the Browser Cache
267
Reset the Ethernet M&C Port
268
Re-Enter the Modem IP Address
268
Change the Encoding
270
Configure Maxthon for the Radyne WEB Browser
271
Change the Browser Mode
272
Change the Encoding
273
Appendix G. Aupc Operation
275
Automatic Uplink Power Control (AUPC Operation
275
Radyne AUPC
275
Ef Aupc
276
Near Side AUPC
276
Appendix H. Drop and Insert (D&I
279
Drop and Insert (D&I
279
Drop Only
281
Insert Only
281
Mode Selection
282
Pcm-30C
282
Pcm-31C
282
T1-D4/T1-D4-S
283
T1-Esf/T1-Esf-S
283
Multidestinational Systems
283
Drop and Insert Mapping
284
Configuring the Modem for Drop and Insert
286
Data Rate
286
Operational Network Specification
287
Terrestrial Framing - Drop Mode/Insert Mode
287
Insert Terrestrial Frame Source
287
D&I Sample Configurations and D&I Clock Setup Options
288
D&I Maps and Map Editing
291
Appendix I. Efficient Drop and Insert (D&I
296
Efficient Drop & Insert Mode
296
Calculating the Required Satellite Bandwidth
297
Calculating the Basic Efficient D&I Rate
297
Calculating the Efficient D&I Rate with E1 Signaling
297
Calculating the Efficient D&I Rate with Enhanced Asynchronous Overhead
297
Summary and Examples
298
Appendix J. Ethernet Data Interface Setup
301
Configure the Modem to Use the Ethernet Data Interface (Optional
301
Ethernet Flow Control
301
Half-Duplex Flow Control
302
Full-Duplex Flow Control
302
Ethernet Daisy Chain
302
Ethernet QOS Type
302
Ethernet QOS Queue
302
Set up the Ethernet Bridge to Operate Like a FIFO
303
Packet Statistics
304
Metric Conversions
305
Advertisement
Radyne DMD20 LBST Installation And Operation Manual (205 pages)
Universal
Brand:
Radyne
| Category:
Modem
| Size: 3 MB
Table of Contents
Installation and Operation Manual
1
Table of Contents
8
Section 1 - Introduction
18
DMD20 Configurations
19
Feature Upgrades
19
Features/Options Installed at Time of Order
19
Function Accessibility
20
Hardware Options
20
Radyne Installed Options
20
1 Overview
18
Section 2 - Installation
22
Mounting Considerations
23
Removal and Assembly
23
Unpacking
23
DMD20 Initial Configuration Check
24
Initial Power-Up
25
Modulator Checkout
25
Factory Terminal Setup
26
Storage
26
2 Installation Requirements
22
Section 3 - Theory of Operation
28
DMD20 Baseband Processing Printed Circuit Card
29
DMD20 Functional Block Diagram
30
Enhanced Interface Printed Circuit Card
30
Baseband Processing
31
Front Panel
31
Tx Baseband Processing
31
Monitor & Control (M&C) Subsystem
32
Rx Baseband Processing
32
Async Port
33
Clock
33
Earth Station to Earth Station Communications Port
33
Ethernet Port
33
Modem Status
33
Remote/Terminal Port
33
Terrestrial Loopback
33
Baseband Processing
34
Baseband Processor Card
34
Clock Selection
37
DMD20 Clocking Options
37
BNC EXC: BNC External Clock
38
EXT CLK: External Clock
38
IDI: Insert Data in
38
SCR: Serial Clock Receive
38
SCT: Serial Clock Transmit
38
SCTE: Serial Clock Transmit External
38
Ethernet Data Interface (Optional)
39
EXT CLK as TX Clock Source (RS-422 or V.35 Interface)
39
Interface
39
Receive Timing
39
SCT or SCTE
39
Transmit Timing
39
Drop and Insert (D&I)
40
Ethernet Data Interface (Optional)
40
Interface or Asymmetrical Data Rates
40
Loop Timing
40
Receive
40
Transmit (RS-422 or V.35 Interface)
40
Drop Only
42
Insert Only
42
Mode Selection
43
Pcm-30C
43
Multidestinational Systems
44
Pcm-31C
44
T1-D4/T1-D4-S
44
T1-Esf/T1-Esf-S
44
Drop and Insert Mapping
45
Reed-Solomon Codec
47
Interleaving
48
Reed-Solomon Code Rate
48
Reed-Solomon Operation in the DMD20
48
DMD20 Automatic Uplink Power Control (AUPC Operation)
49
Asynchronous Overhead Operation (Framing/Multiplexer Capability)
51
Standard IBS Mode
52
Asynchronous Multiplexer Mode
53
ESC Backward Alarms
53
Satellite Control Channel (SCC)
54
SCC Framing Structure
54
To Disable the ESC Backward Alarms
54
Aggregate Data Rate
55
Overhead Rate Comparison
55
Actual Overhead Rate Calculation
56
SCC Overhead Channel Setup
57
Locating the DMD2050 ID Code Operational Procedure
58
Front Panel User Interface
60
3 DMD20 Hardware
28
DMD20 L-Band/If Printed Circuit Card
28
Section 4 - User Interfaces
60
4 User Interfaces
60
Cursor Control Arrow Keys
61
LCD Front Panel Display
61
Numeric Keypad
61
Front Panel LED Indicators
62
Parameter Setup
62
Front Panel Control Screen Menus
63
Main Menus
63
Modulator Menu Options and Parameters
64
Demodulator Menu Options and Parameters
70
Interface Menu Options and Parameters
74
AUPC Menu Options and Parameters
79
Monitor Menu Options and Parameters
81
Alarms Menu Options and Parameters
83
System Menu Options and Parameters
92
Test Menu Options and Parameters
98
DMD20 Strap Codes
100
Sample DMD20 Applications
103
Operational Case Examples
104
Configuring the DMD20 for Drop and Insert
107
Data Rate
108
Operational Network Specification
108
Insert Terrestrial Frame Source
109
Terrestrial Framing - Drop Mode/Insert Mode
109
D&I Sample Configurations and D&I Clock Setup Options
110
D&I Maps and Map Editing
113
Configuring the DMD20 to Use the Ethernet Data Interface (Optional)
116
Ethernet Daisy Chain
117
Ethernet Flow Control
117
Full-Duplex Flow Control
117
Half-Duplex Flow Control
117
Packet Statistics
118
Modem Terminal Mode Control
119
Terminal Mode Control
119
Connecting the Terminal
120
Modem Setup for Terminal Mode
120
Terminal Port User Interface
120
Terminal Screens
121
Section 5 - Rear Panel Interfaces
134
AC Power Input Module
135
Compact Flash
135
Power Input Modules
135
DC Power Input/Switch
136
DMD20 Chassis Connections (Standard)
136
Ext Ref (J10)
136
Rx if (J13)
136
RX L-Band if (J14)
136
Tx if (J11)
136
TX L-Band if (J12)
136
Alarm (J15)
137
Ext Clk (J16)
137
Async (J17)
138
J19)
138
Terminal (J18)
138
Remote (J20)
139
DMD20 LBST Chassis Connections (Standard)
140
Ethernet (J21)
140
Ext Ref (J10)
140
Rx (J14)
140
Tx (J11)
140
Alarm (J15)
141
Ext Clk (J16)
141
Async (J17)
142
J19)
142
Terminal (J18)
142
Ethernet (J21)
143
Remote (J20)
143
Esc Alarm (J1)
144
IDR/IBS Interface (Optional)
144
Audio (J2)
145
Bal (J4)
146
Data (J3)
146
Switch Interface (J5)
147
Ddo (J7)
150
Ethernet Data Interface (Optional)
150
High-Speed Serial Interface (HSSI) (Optional)
150
IDI (J8)
150
Sd (DDI) (J6)
150
Sd (Ido) (J9)
150
Hssi (J6)
151
Asi in (J1)
152
Asi out (J2)
152
ASI/DVB/M2P Interface (Optional)
152
Dvb/M2P in (J3)
152
Dvb/M2P out (J4)
154
Ethernet Data Interface (Optional)
156
Clock Adjustment
158
5 DMD20 Connections
134
Section 6 - Maintenance and Troubleshooting
158
Troubleshooting
158
Alarm Faults
159
Major Tx Alarms
159
Major Rx Alarms
160
Minor Tx Alarms
160
Minor Rx Alarms
161
Common Major Alarms
162
Drop and Insert Alarms
162
Active Alarms
163
Alarm Masks
163
Common Equipment Faults
163
Latched Alarms
163
Major Alarms
163
Minor Alarms
163
Backward Alarms
164
IBS Fault Conditions and Actions
164
6 Periodic Maintenance
158
Section 7 - Technical Specifications
166
Demodulator
167
DMD20 Drop and Insert (Optional)
167
Monitor and Control
167
Plesiochronous Buffer
167
Asi
168
Dvb/M2P
168
Environmental
168
Ethernet Data Interface (Optional)
168
High-Speed Serial Interface (HSSI)
168
Ibs/Synchronous Interface (Standard)
168
IDR/ESC Interface (Optional)
168
Physical
168
Terrestrial Interfaces
168
DMD20 Data Rate Limits
169
Non-DVB
169
Dvb
170
BER Performance (Viterbi)
172
DMD20/DMD20 LBST BER Specifications
172
BER Performance (Sequential)
173
BER Performance (Viterbi with Reed-Solomon)
174
BER Performance (Turbo)
175
BER Performance (8PSK Trellis)
176
BER Performance (8PSK Turbo)
177
BER Performance (16QAM Viterbi)
178
BER Performance (16QAM Viterbi with Reed-Solomon)
179
BER Performance (16QAM Turbo)
180
BER Performance ((O)QPSK Turbo)
181
BER Performance (8PSK Turbo)
182
BER Performance (16QAM Turbo)
183
Input Level
188
ACG Output Voltage
189
7 Data Rates
166
Modulator
166
Appendix A - Product Options
190
ASI/LVDS Parallel
190
ASI/RS-422 Parallel
190
DC Input Prime Power
190
Ethernet Data Interface
190
G.703/IDR ESC Interface
190
Hardware Options
190
Hssi
190
Internal High Stability
190
Turbo Card
190
AS/5167 Super Card (Variable Reed-Solomon)
191
Custom Reed-Solomon
191
Customized Options
191
Appendix B - Front Panel Upgrade Procedure
192
Introduction
192
Required Equipment
192
Upgrade Procedure
192
Canceling Demonstration Mode
194
Demonstration Procedure
194
Appendix C - Carrier Control
198
Carrier Auto
198
Carrier off
198
Carrier on
198
Carrier Vsat
198
States
198
Carrier RTS
199
Glossary
200
Radyne DMD20 LBST Installation And Operation Manual (189 pages)
Universal Satellite Modem
Brand:
Radyne
| Category:
Modem
| Size: 1 MB
Table of Contents
Installation and Operation Manual
1
Table of Contents
7
Section 1 - Introduction
15
Feature Upgrades
16
Features/Options Installed at Time of Order
16
Function Accessibility
16
Hardware Options
16
Radyne Comstream Installed Options
16
1 Overview
15
DMD20 Configurations
15
Section 2 - Installation
17
Mounting Considerations
18
Removal and Assembly
18
Unpacking
18
DMD20 Initial Configuration Check
19
Initial Power-Up
20
Modulator Checkout
20
Storage
21
Terminal Setup
21
2 Installation Requirements
17
Section 3 - Theory of Operation
23
DMD20 Baseband Processing Printed Circuit Card
24
DMD20 Functional Block Diagram
26
Enhanced Interface Printed Circuit Card
26
Front Panel
26
Baseband Processing
27
Clock Selection
27
Rx Baseband Processing
27
Tx Baseband Processing
27
Monitor & Control (M&C) Subsystem
28
Terminal
28
Async Port
29
Clock
29
Earth Station to Earth Station Communications Port
29
Ethernet Port
29
Modem Status
29
Remote Port
29
Terrestrial Loopback
29
Baseband Processing
30
Baseband Processor Card
30
BNC EXC: BNC External Clock
33
DMD20 Clocking Options
33
EXT CLK: External Clock
33
IDI: Insert Data in
33
SCR: Serial Clock Receive
33
SCT: Serial Clock Transmit
33
SCTE: Serial Clock Transmit External
33
EXT CLK as TX Clock Source (RS-422 or V.35 Interface)
34
EXT if REF: External if Reference
34
Interface
34
Loop Timing
34
Receive Timing
34
SCT or SCTE
34
Transmit Timing
34
Drop and Insert (D&I)
35
Interface or Asymmetrical Data Rates
35
Receive
35
Transmit (RS-422 or V.35 Interface)
35
Drop Only
37
Insert Only
37
Mode Selection
38
Pcm-30C
38
Drop and Insert Mapping
39
Multidestinational Systems
39
Pcm-31C
39
T1-D4/T1-D4-S
39
T1-Esf/T1-Esf-S
39
Interleaving
42
Reed-Solomon Code Rate
42
Reed-Solomon Codec
42
Reed-Solomon Operation in the DMD20
42
DMD20 Automatic Uplink Power Control (AUPC Operation)
44
Asynchronous Overhead Operation (Framing/Multiplexer Capability)
45
Standard IBS Mode
46
Asynchronous Multiplexer Mode
47
ESC Backward Alarms
47
To Disable the ESC Backward Alarms
47
Front Panel User Interface
49
3 DMD20 Hardware
23
DMD20 L-Band/If Printed Circuit Card
23
Section 4 - User Interfaces
49
4 User Interfaces
49
Cursor Control Arrow Keys
50
LCD Front Panel Display
50
Numeric Keypad
50
Front Panel LED Indicators
51
Parameter Setup
51
Front Panel Control Screen Menus
52
Main Menus
52
Modulator Menu Options and Parameters
52
Demodulator Menu Options and Parameters
55
Interface Menu Options and Parameters
58
AUPC Menu Options and Parameters
60
Monitor Menu Options and Parameters
62
Alarms Menu Options and Parameters
63
System Menu Options and Parameters
69
Test Menu Options and Parameters
73
DMD20 Strap Codes
75
Sample DMD20 Applications
79
Operational Case Examples
80
Configuring the DMD20 for Drop and Insert
83
Data Rate
83
Operational Network Specification
84
Terrestrial Framing - Drop Mode/Insert Mode
84
D&I Sample Configurations and D&I Clock Setup Options
85
Insert Terrestrial Frame Source
85
D&I Maps and Map Editing
89
Modem Setup for Terminal Mode
92
Modem Terminal Mode Control
92
Terminal Mode Control
92
Host Computer Remote Communications
93
Modem Remote Communications
93
Protocol Wrapper
94
Frame Description and Bus Handshaking
96
Global Response Operational Codes
97
Collision Avoidance
100
Software Compatibility
102
Rllp Summary
103
AC Power Input Module
105
Section 5 - Rear Panel Interfaces
105
Audio (J2)
106
Bal (J4)
108
Data (J3)
108
Switch Interface (J5)
109
Ddo (J7)
112
Ext Ref (J10)
112
IDI (J8)
112
Sd (DDI) (J6)
112
Sd (Ido) (J9)
112
Tx if (J11)
112
TX L-Band if (J12)
112
Alarm (J15)
113
Ext Clk (J16)
113
Rx if (J13)
113
RX L-Band if (J14)
113
Async (J17)
114
Terminal (J18)
114
J19)
115
TM103 - Rev
115
Compact Flash
116
Ethernet (J21)
116
Location J22 (Optional)
116
Remote (J20)
116
Clock Adjustment
118
5 DMD20 Connections
105
Esc Alarm (J1)
105
Section 6 - Maintenance and Troubleshooting
118
Troubleshooting
118
Alarm Faults
119
Major Tx Alarms
119
Major Rx Alarms
120
Minor Rx Alarms
121
Minor Tx Alarms
121
Drop and Insert Alarms
122
Alarm Masks
123
Common Major Alarms
123
Active Alarms
124
Backward Alarms
124
Common Equipment Alarms
124
DMD20 Fault Tree Matrices
124
IBS Fault Conditions and Actions
124
Interpreting the Matrices
124
Latched Alarms
124
Major Alarms
124
Minor Alarms
124
6 Periodic Maintenance
118
Section 7 - Technical Specifications
128
BER Performance
129
DMD20 Drop and Insert (Optional)
129
Monitor and Control
129
Plesiochronous Buffer
129
DMD20 Data Rate Limits
130
Environmental
130
Ibs/Synchronous Interface (Standard)
130
IDR/ESC Interface (Optional)
130
Physical
130
Terrestrial Interfaces
130
8PSK Trellis Decoder 8PSK
132
DMD20 BER Specifications
132
Modem BER Performance (Viterbi)
132
Trellis Decoder and Reed-Solomon
132
Concatenated Reed-Solomon Performance (BER Specifications)
133
QAM BER Performance (Viterbi Decoder)
133
Sequential Decoder BER Performance (1.544 Mbps)
133
BER Charts
134
QAM BER Performance (Viterbi Decoder W/ Reed-Solomon)
134
7 Data Rates
128
Demodulator
128
Modulator
128
Appendix A - Product Options
138
ASI/LVDS Parallel
138
ASI/RS-422 Parallel
138
Customized Options
138
DC Prime Power
138
G.703/IDR ESC Interface
138
Hardware Options
138
Hssi
138
Internal High Stability
138
Turbo Card
138
Appendix B - Remote Operations
140
DMD20 Opcode Command Set
140
Modem Command Set
140
Detailed Command Descriptions
144
DMD20 Modulator
144
DMD20 Demodulator
161
Appendix C - SNMP MIB
182
Advertisement
Advertisement
Related Products
Radyne DMD20LBST
Radyne DMD2401 IBS
Radyne ComStream DMD2401L
Radyne DMD2050
Radyne DMD2401 LB
Radyne DMD2401 ST
Radyne ComStream DMD2401 IDR
Radyne DMD15
Radyne DMD50
Radyne DMD15 IBS
Radyne Categories
Modem
Modulator
Switch
Amplifier
Power Supply
More Radyne Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL