Radyne MM200 Installation And Operation Manual page 123

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
<1>
Channel Setting
<1>
Major Alarm1
Mask
<1>
Major Alarm2
Mask
<1>
Minor Alarm1
Mask
<1>
Minor Alarm2
Mask
<1>
Common Alarm1
Mask
<1>
Common Alarm2
Mask
<1>
Control Mode
<1>
Last Rate Control
<1>
User Mode
<1>
Acquisition Control
<2>
Acquisition Bandwidth
<1>
Acquisition Delay
<1>
Acquisition Step
<1>
Tracking Step
<1>
Re-acquisition Delay
TM086 – Rev. 4.1
0 = auto
1 = one
2 = two
3 = three
4 = four
0 = Mask, 1 = Allow
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bit 2 = Signal Lock Detect
Bit 3 = Sync Lock Detect
Bit 4 = Deframer clock PLL lock detect
Bit 5 = Diversity FPGA fail
Bits 6 – 7 = Spare
0 = Mask, 1 = Allow
Bits 0 – 7 = Spare
0 = Mask, 1 = Allow
Bits 0 – 7 = Spare
0 = Mask, 1 = Allow
Bits 0 – 7 = Spare
0 = Mask, 1 = Allow
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Data FPGA Fail
Bits 2 – 7 = Spare
0 = Mask, 1 = Allow
Bits 0 – 7 = Spare
0 = local
1 = terminal
2 = computer
3 = Ethernet
0 = symbol
1 = data
2 = auto
0 = Debug
1 = All Access
2 = Level 1
3 = Level 2
0 = Off, 1 = Acquire
50 – 400 kHz, 1 kHz steps
10 – 255 sec, 1 sec steps
10 – 100 kHz, 1 kHz steps
10 – 100 Hz, 1 Hz steps
10 – 255 sec, 1 sec steps