Sign In
Upload
Manuals
Brands
Radyne Manuals
Modem
DMD50
Radyne DMD50 Manuals
Manuals and User Guides for Radyne DMD50. We have
2
Radyne DMD50 manuals available for free PDF download: Installation And Operation Manual
Radyne DMD50 Installation And Operation Manual (266 pages)
Universal Satellite Modem
Brand:
Radyne
| Category:
Modem
| Size: 4.94 MB
Table of Contents
Specification
3
Specification
5
Installation and Operation Manual
37
Table of Contents
39
About this Manual
47
Related Documents
47
Electrical Safety
48
Limitations of Warranty
51
Customer Support
52
Chapter 1. Introduction
53
Overview
53
Configurations
54
Factory Installed Options
54
Feature Upgrades
54
Features/Options Installed at Time of Order
54
Function Accessibility
54
Hardware Options
54
Chapter 2. Installation
55
Unpacking and Inspection
55
Installation Requirements
56
Installation Considerations
56
Initial Configuration Check
57
Factory Terminal Setup
58
Initial Power-Up
58
Modulator Checkout
58
Rx Sat Clock
71
EXT REF: External Reference, Top BNC Port, J10
72
Chapter 3. Theory of Operation
59
L-Band/If Printed Circuit Card
59
Modem Hardware
59
Baseband Processing Printed Circuit Card
60
Enhanced Interface Printed Circuit Card
61
Functional Block Diagram
61
Baseband Processing
62
Front Panel
62
Monitor & Control (M&C) Subsystem
63
Rx Baseband Processing
63
Tx Baseband Processing
63
Ethernet M&C Port
64
Modem Remote Communications (RLLP)
64
Terminal Port
64
Async Port / ES-ES Communications
65
Internal Clock
65
Modem Monitor Status
65
2 B L Oopback Features (Terrestrial & IF)
66
Clocking Options
69
TX Clock Options
69
RX Buffer Clock Options
70
RS530/422/V.35 Interface (Standard)
72
Ethernet Data Interface (Optional)
72
HSSI Interface (Optional)
72
Interface (Optional)
72
Interleaving
73
Reed-Solomon Code Rate
73
Reed-Solomon Codec
73
Reed-Solomon Operation
73
Asynchronous Overhead Operation (Framing/Multiplexer Capability)
75
Standard IBS Mode
76
Asynchronous Multiplexer Mode
76
ESC Backward Alarms
77
To Disable the ESC Backward Alarms
77
Doubletalk Carrier-In-Carrier Option
78
What Is Doubletalk Carrier-In-Carrier
78
Application Requirements
79
Operational Recommendations
81
System Functionality and Operational Considerations
82
Doubletalk Carrier-In-Carrier Cancellation Process
84
Carrier-In-Carrier and Adaptive Coding and Modulation
86
Carrier-In-Carrier Latency
86
Carrier-In-Carrier Link Design
86
Margin Requirements
86
Symmetric Data Rate Link
87
Asymmetric Data Rate Link
90
Power Limited Links
91
Carrier-In-Carrier Commissioning and Deployment
92
Validating Carrier-In-Carrier Performance
93
Carrier-In-Carrier Link Budget Calculation
94
Operational References
94
Estimating PSD Ratio
95
Estimating Psd Ratio from Satmaster
96
Estimating Psd Ratio Using Spectrum Analyzer
96
Carrier-In-Carrier Summary
97
Doubletalk Carrier-In-Carrier Specifications
97
Bpsk
97
Glossary
98
Satellite Control Channel (SCC)
100
SCC Framing Structure
100
Aggregate Data Rate
101
Overhead Rate Comparison
101
Actual Overhead Rate Calculation
102
SCC Overhead Channel Setup
103
EDMAC Satellite Framing/Deframing Mode
104
Locating the ID Code Operational Procedure
104
Strap Codes
104
Chapter 4. User Interfaces
105
User Interfaces
105
Cursor Control Arrow Keys
106
Front Panel LED Indicators
106
LCD Front Panel Display
106
Numeric Keypad
106
Front Panel User Interface
105
Parameter Setup
108
Demodulator Menu Options and Parameters
115
Interface Menu Options and Parameters
120
Monitor Menu Options and Parameters
124
Alarms Menu Options and Parameters
126
System Menu Options and Parameters
134
Test Menu Options and Parameters
143
Modem Setup for Terminal Mode
144
Modem Terminal Mode Control
144
Front Panel Control Screen Menus
108
Main Menus
108
Modulator Menu Options and Parameters
108
Terminal Mode Control
144
Terminal Port User Interface
145
Protocol Structure
146
Connecting the Terminal
145
Terminal Screens
146
RS485 Remote Port Interface (RLLP Protocol)
146
Chapter 5. Rear Panel Interfaces
147
Connections
147
AC Power Input Module
148
Compact Flash
148
Power Input Modules
148
Alarm (J15)
149
Chassis Connections (Standard)
149
DC Power Input/Switch
149
Ext Ref (J10)
149
Rx if (J13)
149
RX L-Band if (J14)
149
Tx if (J11)
149
TX L-Band if (J12)
149
4 3 B Async (J17)
150
Ext Clk (J16)
150
J18
151
J19)
151
Ethernet (J21)
152
IDR/IBS Interface (Optional)
152
Remote (J20)
152
Esc Alarm (J1)
153
Audio (J2)
154
K Data (J3)
155
Switch Interface (J5)
156
Ddo (J7)
157
IDI (J8)
157
Sd (DDI) (J6)
157
Sd (Ido) (J9)
157
Bal (J4)
155
Ethernet Data Interface (Optional)
158
High-Speed Serial Interface (HSSI) (Optional)
158
Hssi (J6)
158
Asi in (J1)
159
Asi out (J2)
159
ASI/DVB/M2P Interface (Optional)
159
Dvb/M2P in (J3)
159
Dvb/M2P out (J4)
160
Ethernet Data Interface (Optional)
161
Audio (J2)
162
Bal (J4)
163
Data (J3)
163
Esc Alarm (J5)
164
IDI (J8)
164
Sd (Ido) (J9)
164
HSSI / Ethernet (J1)
165
Ethernet Data Interface
165
Gige Interface
166
Troubleshooting
167
Alarm Faults
168
Major Rx Alarms
168
Major Tx Alarms
168
Minor Tx Alarms
168
Common Major Alarms
169
Alarm Masks
170
Drop and Insert Alarms
169
Minor Rx Alarms
169
Active Alarms
170
Backward Alarms
170
Chapter 6. Maintenance and Troubleshooting
167
Clock Adjustment
167
Periodic Maintenance
167
IBS Fault Conditions and Actions
171
Chapter 7. Technical Specifications
173
Common Equipment Faults
170
Latched Alarms
170
Major Alarms
170
Minor Alarms
170
Data Rates
173
Modulator
173
Demodulator
174
Plesiochronous Buffer
175
Monitor and Control
175
DMD50 Drop and Insert (Optional)
175
Terrestrial Interfaces
175
IDR/ESC T2/E2 Interface (Optional)
175
IDR/ESC T3/E3/STS1 Interface (Optional)
176
Ibs/Synchronous Interface (Standard)
176
High-Speed Serial Interface (HSSI)
176
Asi
176
Dvb/M2P
176
Ethernet Data Interface (Optional)
176
Gigi Ethernet Data Interface (Optional)
176
HSSI / G703 T2/E2 Max
177
HSSI / G703 T3/E3/STS1 Max
177
Hssi /Ethernet
177
Environmental
177
Physical
177
DMD50 Data Rate Limits
178
Non-DVB
178
Qpsk
179
Dvb
180
DMD50 BER Specifications
182
BER Performance (Viterbi)
182
BER Performance (Sequential)
183
BER Performance (Viterbi with Reed-Solomon)
184
BER Performance (Turbo)
185
BER Performance (8PSK Trellis)
186
BER Performance (8PSK Turbo)
187
BER Performance (16QAM Viterbi)
188
BER Performance (16QAM Viterbi with Reed-Solomon)
189
BER Performance (16QAM Turbo)
190
BER Performance ((O)QPSK Turbo)
191
BER Performance (8PSK Turbo)
192
BER Performance (16QAM Turbo)
193
1/2 Rate B/O/QPSK BER Performance (LDPC)
194
2/3 Rate Q/8PSK/8QAM BER Performance (LDPC)
195
3/4 Rate Q/8PSK, 8/16QAM BER Performance (LDPC)
196
ACG Output Voltage
202
Appendix A. Product Options
203
Hardware Options
203
G.703/IDR ESC Interface
203
Internal High Stability
203
DC Input Prime Power
203
ASI/RS-422 Parallel
203
ASI/LVDS Parallel
203
Hssi
203
Ethernet Data Interface
203
Hssi
204
Hssi / Ethernet
204
Turbo Product Code / Variable Reed-Solomon
204
Customized Options
204
Appendix B. Front Panel Upgrade Procedure
205
Introduction
205
Required Equipment
205
Upgrade Procedure
205
Demonstration Procedure
207
Running in Demonstration Mode
209
Canceling Demonstration Mode
210
States
211
Carrier off
211
Carrier on
211
Carrier Auto
211
Appendix C. Carrier Control
211
Carrier Vsat
212
Carrier RTS
212
Appendix D. Web Browser Setup Guide
213
Introduction
213
Change Web User Name
215
Change Authentication Password
215
Change Access Rights
215
Modem Web Site
215
Appendix E. Strap Codes
219
Strap Codes
219
Sample Applications
223
Operational Case Examples
223
Case 1: IDR 8.448 Mbps, 3/4 Rate Viterbi
224
Case 2: IBS 1.544 Mbps, 3/4 Rate Viterbi
225
Case 3: Closed Network, 3/4 Rate Viterbi, IBS Overhead
226
Case 4: Loop Timing Example
227
Appendix F. Tcp/Ip Ethernet Setup
229
Introduction
229
TCP/IP Network Configuration
229
Network Configuration Summary
231
Ethernet Test
231
Connecting the Modem Ethernet Cable to a Network Link
231
Connecting the Modem Ethernet Cable Directly to a Computer (Without a Network
231
Testing the Ethernet Connection Using the Ping Program (Optional
234
Appendix G. Aupc Operation
235
Automatic Uplink Power Control (AUPC Operation
235
Radyne AUPC
235
Ef Aupc
236
Near Side AUPC
236
Appendix H. Drop and Insert (D&I
239
Drop and Insert (D&I
239
Drop Only
241
Insert Only
241
Mode Selection
242
Multidestinational Systems
243
Drop and Insert Mapping
243
Configuring the Modem for Drop and Insert
245
Data Rate
245
Operational Network Specification
246
Terrestrial Framing - Drop Mode/Insert Mode
246
D&I Sample Configurations and D&I Clock Setup Options
248
D&I Maps and Map Editing
251
Appendix I. Efficient Drop and Insert (D&I
255
Introduction
255
Prerequisite
255
Efficient Drop & Insert Mode
256
Calculating the Required Satellite Bandwidth
257
Calculating the Basic Efficient D&I Rate
257
Calculating the Efficient D&I Rate with E1 Signaling
257
Calculating the Efficient D&I Rate with Enhanced Asynchronous Overhead
257
Appendix J. Ethernet Data Interface Setup
261
Configuring the Modem to Use the Ethernet Data Interface (Optional
261
Ethernet Flow Control
261
Ethernet Daisy Chain
262
Ethernet QOS Type
262
Ethernet QOS Queue
262
Setting up the DMD20/DMD20 LBST Ethernet Bridge to Operate Like a FIFO
263
Packet Statistics
264
Metric Conversions
265
Advertisement
Radyne DMD50 Installation And Operation Manual (237 pages)
Universal Satellite Modem
Brand:
Radyne
| Category:
Modem
| Size: 1.69 MB
Table of Contents
Installation and Operation Manual
1
Table of Contents
8
Section 1 - Introduction
18
Feature Upgrades
19
Features/Options Installed at Time of Order
19
Function Accessibility
19
Hardware Options
19
Radyne Installed Options
19
1 Overview
18
Configurations
18
Section 2 - Installation
22
Removal and Assembly
23
Unpacking
23
Initial Configuration Check
24
Mounting Considerations
24
Factory Terminal Setup
26
Initial Power-Up
26
Modulator Checkout
26
Storage
26
2 Installation Requirements
22
Section 3 - Theory of Operation
28
Baseband Processing Printed Circuit Card
29
Enhanced Interface Printed Circuit Card
30
Functional Block Diagram
30
Baseband Processing
31
Front Panel
31
Monitor & Control (M&C) Subsystem
32
Rx Baseband Processing
32
Tx Baseband Processing
32
Ethernet M&C Port
33
Modem Monitor Status
33
Modem Remote Communications (RLLP)
33
Terminal Port
33
Async Port / ES-ES Communications
34
Internal Clock
34
Loopback Features (Terrestrial & IF)
35
Clocking Options
38
TX Clock Options
38
RX Buffer Clock Options
39
SCT: Serial Clock Transmit
39
SCTE: Serial Clock Transmit External
39
EXT CLK/EXT BNC: External Clock, J16
40
EXT IDI: Insert Data in
40
RX SAT Clock
40
SCT: Serial Clock Transmit
40
SCTE: Serial Clock Transmit External
40
Ethernet Data Interface (Optional)
41
EXT REF: External Reference, Top BNC Port, J10
41
HSSI Interface (Optional)
41
Interface (Optional)
41
RS530/422/V.35 Interfafce (Standard)
41
Interleaving
42
Reed-Solomon Code Rate
42
Reed-Solomon Codec
42
Asynchronous Overhead Operation (Framing/Multiplexer Capability)
44
Asynchronous Multiplexer Mode
46
Standard IBS Mode
46
ESC Backward Alarms
47
Satellite Control Channel (SCC)
48
SCC Framing Structure
48
To Disable the ESC Backward Alarms
48
Aggregate Data Rate
49
Overhead Rate Comparison
49
Actual Overhead Rate Calculation
50
SCC Overhead Channel Setup
51
EDMAC Satellite Framing/Deframing Mode
52
Locating the ID Code Operational Procedure
52
Strap Codes
52
Front Panel User Interface
54
3 Hardware
28
L-Band/If Printed Circuit Card
28
Section 4 - User Interfaces
54
4 User Interfaces
54
Cursor Control Arrow Keys
55
LCD Front Panel Display
55
Numeric Keypad
55
Front Panel LED Indicators
56
Parameter Setup
56
Front Panel Control Screen Menus
57
Main Menus
57
Modulator Menu Options and Parameters
58
Demodulator Menu Options and Parameters
64
Interface Menu Options and Parameters
69
Monitor Menu Options and Parameters
74
Alarms Menu Options and Parameters
76
System Menu Options and Parameters
84
Test Menu Options and Parameters
92
Modem Setup for Terminal Mode
94
Modem Terminal Mode Control
94
Terminal Mode Control
94
Terminal Port User Interface
94
Connecting the Terminal
95
RS485 Remote Port Interface (RLLP Protocol)
95
Terminal Screens
95
Ethernet Remote Port Interface (SNMP & Web Browser)
96
Protocol Structure
96
Section 5 - Rear Panel Interfaces
98
AC Power Input Module
99
Chassis Connections (Standard)
99
Compact Flash
99
DC Power Input/Switch
99
Ext Ref (J10)
99
Power Input Modules
99
Rx if (J13)
99
Tx if (J11)
99
TX L-Band if (J12)
99
Alarm (J15)
100
Ext Clk (J16)
100
RX L-Band if (J14)
100
Async (J17)
101
J18
101
J19)
101
Remote (J20)
102
Esc Alarm (J1)
103
Ethernet (J21)
103
IDR/IBS Interface (Optional)
103
Audio (J2)
104
Bal (J4)
105
Data (J3)
105
Switch Interface (J5)
106
Ddo (J7)
109
Ethernet Data Interface (Optional)
109
IDI (J8)
109
Sd (DDI) (J6)
109
Sd (Ido) (J9)
109
High-Speed Serial Interface (HSSI) (Optional)
110
Hssi (J6)
110
Asi in (J1)
111
Asi out (J2)
111
ASI/DVB/M2P Interface (Optional)
111
Dvb/M2P in (J3)
111
Dvb/M2P out (J4)
113
Ethernet Data Interface (Optional)
115
Audio (J2)
116
Data (J3)
117
Bal (J4)
118
Ddo (J7)
119
Esc Alarm (J5)
119
Sd (DDI) (J6)
119
HSSI / Ethernet (J1)
120
IDI (J8)
120
Sd (Ido) (J9)
120
Ethernet Data Interface
121
Gige Interface
121
Clock Adjustment
124
5 Connections
98
Section 6 - Maintenance and Troubleshooting
124
Troubleshooting
124
Alarm Faults
125
Major Tx Alarms
125
Major Rx Alarms
126
Minor Tx Alarms
126
Minor Rx Alarms
127
Common Major Alarms
128
Drop and Insert Alarms
128
Active Alarms
129
Alarm Masks
129
Common Equipment Faults
129
Latched Alarms
129
Major Alarms
129
Minor Alarms
129
Backward Alarms
130
IBS Fault Conditions and Actions
130
6 Periodic Maintenance
124
Section 7 - Technical Specifications
134
Demodulator
135
Monitor and Control
135
Plesiochronous Buffer
135
Asi
136
DMD50 Drop and Insert (Optional)
136
Dvb/M2P
136
Ethernet Data Interface (Optional)
136
High-Speed Serial Interface (HSSI)
136
Ibs/Synchronous Interface (Standard)
136
IDR/ESC Interface (Optional)
136
Terrestrial Interfaces
136
Environmental
137
Hssi / G703
137
Hssi /Ethernet
137
Physical
137
Data Rate Limits
138
Non-DVB
138
Dvb
139
BER Performance (Viterbi)
141
BER Specifications
141
BER Performance (Sequential)
142
BER Performance (Viterbi with Reed-Solomon)
143
BER Performance (8PSK Trellis)
147
BER Performance (8PSK Turbo)
148
BER Performance (16QAM Viterbi)
149
BER Performance (16QAM Viterbi with Reed-Solomon)
150
BER Performance (16QAM Turbo)
151
BER Performance (16QAM Turbo)
152
AGC Output Voltage
157
7 Data Rates
134
Modulator
134
Appendix A - Product Options
160
ASI/LVDS Parallel
160
ASI/RS-422 Parallel
160
DC Input Prime Power
160
Ethernet Data Interface
160
G.703/IDR ESC Interface
160
Hardware Options
160
Hssi
160
Internal High Stability
160
Customized Options
161
Hssi / Ethernet
161
Appendix B - Front Panel Upgrade Procedure
164
Introduction
164
Required Equipment
164
Upgrade Procedure
164
Demonstration Procedure
166
Running in Demonstration Mode
168
Canceling Demonstration Mode
169
Appendix C - Carrier Control
172
Carrier Auto
172
Carrier off
172
Carrier on
172
Carrier Vsat
172
States
172
Carrier RTS
173
Appendix D - Strap Codes
176
Strap Codes
176
Sample Applications
179
Operational Case Examples
180
Appendix E - TCP/IP Ethernet Setup
186
Introduction
186
TCP/IP Network Configuration
186
Connecting the Modem Ethernet Cable to a Network Link
188
Ethernet Test
188
Network Configuration Summary
188
Testing the Ethernet Connection Using the Ping Program (Optional)
191
Appendix F - Web Browser Setup Guide
194
Introduction
194
WEB Users Configuration
194
Change Access Rights
196
Change Authentication Password
196
Change Web User Name
196
Modem Web Site
197
Appendix G - AUPC Operation
202
Automatic Uplink Power Control (AUPC Operation)
202
Radyne AUPC
202
Ef Aupc
203
Near Side AUPC
203
Appendix H - Drop and Insert (D&I)
206
Drop and Insert (D&I)
206
Drop Only
208
Insert Only
208
Mode Selection
210
Pcm-30C
210
Pcm-31C
210
Multidestinational Systems
211
T1-D4/T1-D4-S
211
T1-Esf/T1-Esf-S
211
Drop and Insert Mapping
212
Configuring the Modem for Drop and Insert
214
Data Rate
214
Operational Network Specification
215
Terrestrial Framing - Drop Mode/Insert Mode
215
D&I Sample Configurations and D&I Clock Setup Options
216
Insert Terrestrial Frame Source
216
D&I Maps and Map Editing
220
Appendix I - Efficient Drop & Insert
226
Introduction
226
Prerequisite
226
Efficient Drop & Insert Mode
227
Calculating the Basic Efficient D&I Rate
228
Calculating the Efficient D&I Rate with E1 Signaling
228
Calculating the Efficient D&I Rate with Enhanced Asynchronous Overhead
228
Calculating the Required Satellite Bandwidth
228
Glossary
232
Advertisement
Related Products
Radyne DMD15L IBS
Radyne DMD20 LBST
Radyne DMD20LBST
Radyne DMD2050
Radyne DMD2401 ST
Radyne DMD15 IBS
Radyne DMD15L IDR
Radyne ComStream DMD2401 IDR
Radyne DMD15 IDR
Radyne DMD2401 LB
Radyne Categories
Modem
Modulator
Switch
Amplifier
Power Supply
More Radyne Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL