Appendix A
<1>
Reserved
Opcode: <0x2143>
<1>
Selected interface
number
<1>
Selected
interface number
<1>
Jitter Control
Opcode: <0x2160>
<1>
Selected interface
number
<1>
Selected
interface number
<1>
Interface Major
Alarm1
<1>
Interface Minor
Alarm1 Status
<1>
Interface Latched
Major Alarm1 Status
<1>
Interface Latched
A-30
4 = T3E3
5 = T1E1
6 = DSO
7 = PAR
8 = OC3
9 = HSSI
10 = SMPTE
11 = P10BaseT
12 = T2E2
Spare
Query selected Tx interface jitter control
Command Data Field 1 Byte
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Query Response
0 = interface1
1 = interface2
2 = interface3
3 = interface4
0 = Normal, 1 = Stamp2, 2 = Stamp3
Query selected Rx interface status
Command Data Field 1 Byte
0 = interface1
1 = interface2
2 = interface3
3 = interface4
Query Response
0 = interface1
1 = interface2
2 = interface3
3 = interface4
0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 - 7 = Spare
0 = Pass, 1 = Fail
Bit 0 = Interface Test
Bit 1 - 7 = Spare
0 = Pass, 1 = Fail
MM200 High-Speed Microwave Modem
TM086 – Rev. 4.1

Advertisement

Table of Contents
loading