Radyne MM200 Installation And Operation Manual page 168

Mm200 high speed microwave modem
Table of Contents

Advertisement

Appendix B
radMM200RxLatchedMajorAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 6 }
radMM200RxLatchedMinorAlarm1Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = Spare
Bit 1 = Spare
Bit 2 = Spare
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 7 }
radMM200RxLatchedMinorAlarm2Status OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0..7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200DemodStatus 8 }
radMM200RxMaxPayload OBJECT-TYPE
SYNTAX INTEGER (0..200000000)
MAX-ACCESS
STATUS current
DESCRIPTION
"Maximum payload at current demodulation."
::= { radMM200DemodStatus 9 }
radMM200RxPercentUtilization OBJECT-TYPE
SYNTAX INTEGER (0..65536)
MAX-ACCESS
STATUS current
DESCRIPTION
"% utilization, implied decimal point.
(i.e. 7985 means 79.85%"
::= { radMM200DemodStatus 10 }
radMM200RxBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..40000000)
MAX-ACCESS
STATUS current
DESCRIPTION
"Current bandwidth usage."
::= { radMM200DemodStatus 11 }
radMM200RxInputLevel OBJECT-TYPE
SYNTAX INTEGER (-1000..100)
B-20
read-only
read-only
read-only
read-only
read-only
read-only
MM200 High-Speed Microwave Modem
TM086 – Rev. 4.1

Advertisement

Table of Contents
loading