Radyne MM200 Installation And Operation Manual page 137

Mm200 high speed microwave modem
Table of Contents

Advertisement

MM200 High-Speed Microwave Modem
Opcode: <0x2208>
<1>
Common Alarm1
Mask
<1>
Common Alarm2
Mask
Opcode: <0x2209>
<1>
Last Rate Control
Opcode: <0x220A>
<1>
Frequency Plan
Opcode: <0x220B>
<1>
User Mode
Opcode: <0x220C>
<1>
Mux Loopback
Opcode: <0x220D>
<1>
Repeater Mode
Opcode: <0x2240>
<4>
IF Frequency
Opcode: <0x2241>
<4>
Data Rate
TM086 – Rev. 4.1
Command set common alarm mask
Command Data
0 = Mask, 1 = Allow
Bit 0 = Glue Logic FPGA Fail
Bit 1 = Test FPGA Fail
Bits 2 – 7 = Spare
0 = Mask, 1 = Allow
Bit 0 – 7 = Spare
Command set last rate control
Command Data
0 = Symbol
1 = Data
2 = Auto
Command frequency plan
Command Data
0 = Auto, 1 = User
Command user mode
Command Data
0 = Reserved
1 = All Access
2 = Level 1
3 = Level 2
Note: Higher user levels restrict access to system control
parameters but allow higher levels of automation
Command mux loopback
Command Data
0 = Normal, 1 = Mux/Dmx Loop, 2 = Mux/Dmx LVDS,
3 = Modem LVDS, 4 = Repeater
Note: This command is not valid if the MM200 is in
Repeater Mode.
Command repeater mode
Command Data
0 = Off, 1 = On
Command modulator frequency
Command Data
50000000 - 90000000
Command modulator data rate
Command Data
70000000 - 200000000
Appendix A